A camera streams normally and its controller can read deserializer status. During a power-mode transition, the receiver occasionally loses a frame. An oscilloscope connected after the fault shows a clean 25 MHz oscillator. The useful question is whether the deserializer received valid edges continuously during the transition. A clock that has recovered before measurement can still have missed part of the video or back-channel activity. Align the reference supply, received clock, and video error on one time axis before replacing the oscillator or changing initialization.
Verify clock continuity at the deserializer input
TI specifies a continuous 23 MHz to 26 MHz REFCLK for precise frequency operation. This reference contributes to internal timing, the back-channel rate, control-interface timing, CSI-2 data rate, and frame synchronization. The data sheet notes that an input with no detected transition for more than 20 microseconds can disrupt CSI-2. That gives a relevant time scale for investigation. It does not quantify the behavior of every possible interruption, nor establish that every shorter gap is acceptable to the system.
At 25 MHz, one nominal period is 40 ns. A measured interval of 24 microseconds between the last valid edge and the next valid one equals about 600 nominal periods and exceeds the 20 microsecond condition identified by TI. This is a time-to-period comparison. It does not establish how many video packets or frames were lost. That depends on the input stream and configuration. Set the scope trigger to a valid receiver threshold when looking for missing edges. A clean monitoring point next to the oscillator can miss a downstream buffer shutdown or a disturbed clock at the load.
A valid frequency reading can coexist with a past gap
The data sheet describes a backup internal oscillator nominally at 25 MHz with a ±10% figure during startup. It does not qualify the external reference. TI separately documents REFCLK_FREQ as a frequency measurement in MHz. Because the measurement is asynchronous to the read, TI says to accept the value only when two consecutive reads agree. That rule addresses the validity of a read. Two matching readings do not rule out a microsecond-scale interruption between them. Use the register trace to assist interpretation of the waveform rather than to replace it.
Examine the full clock path before changing the part. If a new surface-mount active oscillator has a different supply or enable, identify what controls it in each system state. An oscillator can continue running while an FPGA or buffer disables the signal that reaches the deserializer. TI also calls for applying REFCLK only when the supply rails meet the corresponding conditions. Do not drive an unpowered input simply to avoid a clock gap. Define which power states must maintain active video and which are designed to stop and restart it. They have different criteria for clock and data recovery.
Qualify the transition as a system event
A controlled alternate source can help isolate the path if it meets input swing, loading, and sequencing requirements. Keep the camera and software unchanged and repeat the power transition. If failures occur only with the original path, investigate the oscillator, buffer, and rails separately. On the actual board, examine REFCLK at the receiver alongside the final buffer enable and power waveforms. Record the receiver voltage, frequency, duty-cycle conditions, and continuity for each oscillator sample. A bench measurement at the oscillator alone does not include the path that installed hardware uses.
Save receiver frames or sequence numbers. Record missed frames, any loss of lock, and the first valid image afterward. CSI-2 transmitter status can help reconstruct the sequence. Include the polling cadence in the record because it limits event timing. If brief video interruption is permitted, qualify the recovery time separately. When replacing the 25 MHz active oscillator, first verify its behavior under the installed load, then repeat the power transitions and sustained video test. The first check establishes availability of the reference, and the second establishes the result at the application boundary.
As additional controls, test cable disturbance and an ordinary software mode change independently. If an image error occurs while the reference edges remain valid, investigate incoming data and transmitter state. If a reference gap is present, identify which power or control event coincides with it before assigning the fault to the oscillator. A capture made on the existing board can then be repeated on a smaller oscillator package or a later board revision.
If two camera channels are present, record which one loses valid output first. A shared reference can affect both, but a common downstream pause can have a similar symptom. Give both streams, the input clock, and the power transition a common time origin.