A USB hub uses a separate 25 MHz active oscillator. On the first connection, it occasionally fails to enumerate. Pressing reset makes the device appear. A probe connected after the fault often shows a clean 25 MHz waveform, but the important event has already passed. USB5744 requires a stable reference before reset release. A frequency measurement taken later cannot establish that earlier condition. Capture oscillator power, the received clock, reset at the device, and the host's enumeration result during one cold start before changing either the clock circuit or subsequent configuration.
Oscillator readiness and reset release are separate events
Microchip's external reset timing diagram gives a 5 microsecond minimum RESET_N assertion and at least 1 millisecond of strap hold following release. A note requires the clock input to be stable before release. The pulse width makes the reset recognizable. The already-stable reference lets initialization start with a suitable clock. The strap hold preserves the values for the chip to read. Meeting the width requirement alone does not establish the other two conditions. If startup uses only power-on reset, use the timing appropriate to that mode.
The device enters standby while RESET_N remains asserted. Transactions stop and internal configuration is lost. After release, the initialization sequence describes PLL lock with a valid clock and then loading configuration. A successful manual reset proves that a later initialization succeeded. The first start may still have failed on power, straps, or reference readiness. Save the time of the first successful detection in the host log and correlate it with the actual reset edge instead of treating a manual reset as the repair.
Calculate margin using when the input really becomes stable
For an illustrative budget, define time zero at the chosen supply threshold for the oscillator. Assume the worst observed sample first delivers valid frequency, amplitude, and waveform at 1.8 ms, and external reset releases at 1.2 ms. The reset pulse may already be much longer than 5 microseconds, yet release precedes readiness by 0.6 ms. A modified release at 2.4 ms gives 0.6 ms of waiting margin for these assumed observations. That absolute release time is not a guarantee for other boards. Use actual rail ramp, oscillator spread and reset threshold variation to build a production budget. Check strap hold after release separately.
The first edge does not necessarily mean the clock is ready. Define a valid continuous waveform at the actual USB5744 XTALI receiver node. Microchip's hardware checklist shows that node for a single-ended source and leaves XTALO open. On a conversion from a passive crystal, check whether old loading or jumpers stayed connected. A 25 MHz oscillator has a nominal 40 ns period. Use a short capture to inspect startup transitions and a longer trace to compare clock readiness and the millisecond reset sequence. Each view answers a different question.
Use controlled restarts to locate the failing step
Start with the original board and compare a fully discharged cold start, external reset with power retained, and rapid power cycling if the product supports it. If only the cold start fails, extend reset through a permitted control path and see whether the result changes as the clock window changes. This is evidence for one part of the failure path. Inspect the straps and host enumeration as well. If all conditions fail, a confirmed suitable clock gives a basis for investigating what happens during configuration and external firmware selection.
Check what the hub actually does after reset. A useful trace shows re-enumeration, negotiated interface speed, and downstream port behavior. A power indicator alone cannot establish that. Compare old and replacement oscillators with the same load and supply transitions. Record the original input measurements together with latest observed readiness, earliest reset release, and the resulting margin. Steady frequency is one entry for the 25 MHz active oscillator. The cold-start criterion also requires the usable clock to be present when the device begins initializing.
Plan the fixture so it distinguishes a USB detach from a complete hub power cycle. Unplugging the cable can cause new enumeration without restarting the reference oscillator on a separately powered board. For cold-start tests, bring the relevant rails to the product's defined off state, then restore them at the slowest and fastest supported ramp rates. Check for partial power supplied via the USB cable after turning off the main power. Reconnecting a cable repeatedly with an already valid clock cannot test cold startup after substitution. Keep logic-only reset trials in a separate group and verify the configuration sequence in each mode.