Two nominal 26 MHz passive crystals meet frequency in an incoming fixture, but one shows a frequency shift with a different oscillator drive setting on the board. Separate crystal excitation from load and temperature. Changing driver configuration can also change supply, effective capacitance, or chip temperature. A suitable fixture can hold termination constant, vary the actual excitation, and check the reading after returning to the original level.
The generator setting differs from power in the crystal
IEC 60444-6 describes drive-level dependence methods based on a pi network, reflection, or an oscillator under applicable conditions. Select the method appropriate to the device, fixture, and inspection agreement. Generator power refers to its specified reference conditions. Loss, mismatch, and coupling affect the power delivered to the crystal. If the effective resistance changes, two generator settings alone do not give the dissipation ratio.
For an illustrative 45 Ω effective resistance matched to the measured current definition, 10 µW corresponds to about 0.471 mA RMS and 40 µW to about 0.943 mA RMS. Four times the power requires twice the current. If resistance differs between levels, calculate each separately. Use only excitation levels supported by the actual crystal and test method.
Return to the low setting
Suppose a fixture reads 26,000,012 Hz at low drive, then 26,000,096 Hz at the higher level. The difference is 84 Hz, or about +3.23 ppm. Returning to low drive yields 26,000,016 Hz, just 4 Hz from the start. If bench repeatability is of that order, the reading largely returns with excitation. If it instead stays near 26,000,090 Hz, investigate settling, contact, and test order. A residual in one run does not establish permanent damage. Keep traces and control readings and repeat on the same unit. The shift can also have a different sign.
Measure across the actual resonance. If the main peak is narrow, a search window or coarse grid can lose it when drive changes. Save the complex response near resonance with frequency and impedance data. Preserve intermediate readings after each level change and use consistent settling conditions. This reveals runs that sampled partway through a thermal transient.
Separate fixture behavior from the assembled board
On a representative board, use the intended oscillator mode. Measure frequency and resistance in the fixture, then compare the board through an allowed buffered output. Verify board drive and actual loading by the applicable methods. If the fixture shows only a few hertz of movement while the board shifts by more than eighty, investigate load capacitors, driver-dependent internal capacitance, and supply. If several crystals show a similar shift in the fixture, share their matched excitation, load, and temperature records with the supplier. Check that probing and supply changes did not alter the board conditions.
Treat allowable initial frequency and drive-induced variation as separate requirements. At 26 MHz, an illustrative two-ppm allowance corresponds to 52 Hz. Two endpoints can independently meet initial tolerance while violating that movement budget. Return to baseline in one test does not settle temperature corners, startup, or lot variation. Record serial numbers, load verification, level sequence, settling, rail voltage, and actual drive. The record supports a reproducible choice between changing crystal and revising the oscillator configuration.
For a multilevel test, plot signed frequency by drive level for each device. Endpoint slope alone can hide a localized shift. Check whether effective resistance changes when sweeping back. A jump in the reported frequency without corresponding movement of the main response warrants checking the fit. If complex impedance and peak both change, investigate neighboring modes and actual loading.
Exercise the same sequence with a check crystal before testing the device. Avoid combining low and high results from different benches. Source attenuation changes can affect matching, isolation, and signal-to-noise ratio, so verify excitation and timebase. Record whether the measurand is frequency at a specified load or series resonance. Compare those quantities only under a common definition.