A 26 MHz VCTCXO cannot reach full pull. Does the DAC voltage reach its control pin?

A programmable voltage sweeps two 26 MHz voltage-controlled temperature-compensated oscillators. One reaches the tuning target and the other does not. When a low-impedance source drives the control pin directly, their curves are close. Measure the voltage at that pin relative to oscillator ground before rejecting the part. Filter resistance, switching paths, and input current can produce different pin voltages for the same code. A plot against command values combines driver and oscillator behavior.

Measure at the control pin after settling

Epson's TG2016SKA specifications list a minimum 500-kilohm DC input impedance from Vc to ground for the voltage-controlled option. They also define control-voltage conditions for several supplies. This is one specific product. Another may specify impedance, leakage, or an external circuit. Check the full part number and use its required supply and output load when measuring frequency.

Suppose the source has 100 kilohms effective series resistance and an open-circuit setting of 1.20 V. Approximate the control input as 500 kilohms to ground. The pin voltage is 1.20 times 500 divided by 600, about 1.00 V. The difference is 0.20 V. If the measured local slope is +15 ppm per volt, the oscillator is about 3 ppm below the prediction made from open-circuit voltage. At 26 MHz that is about 78 Hz. The resistor model and slope are assumptions to verify in the real circuit.

Record DAC output and oscillator control pin after the filter, with the reference ground for each. Clamps, protection components, switches, and bias networks can make input current nonlinear. An effective resistance inferred at one point may not apply across the range. Compare several allowed steady points and see whether the difference increases near one endpoint or only at particular temperatures. This helps trace where the current flows.

Check the additional meter load

In the same model a 10-megohm voltmeter in parallel with 500 kilohms gives about 476 kilohms. It moves the pin from about 1.000 V to 0.992 V. At the assumed slope, attaching the meter shifts frequency by about 3.2 Hz. For a tight test this is relevant. Confirm the meter's input impedance on the selected range, including any change introduced by autoranging.

Save a frequency record before and after connecting the voltmeter. If the new voltage measurement changes oscillator frequency, check burden, reference connection, and stray leakage. Contamination, moisture, and insulation can influence high-impedance nodes. A higher-impedance instrument or an appropriate buffered measurement can help. Verify the buffer's own bias and drift. Probe capacitance can also change settling on a filtered control node.

Compare two versions of the tuning curve

Plot frequency against both DAC code and measured pin voltage. If the original and substitute differ against code but agree against measured voltage, investigate the driver and its load. If they differ at the same Vc, temperature, and supply, compare measured slope, center offset, and endpoint range with the appropriate oscillator specification. Where the board supports an open-loop test, a qualified low-impedance source can separate oscillator behavior. Keep voltages within limits and use the intended isolation provisions.

Wait longer at a fixed control setting and check whether frequency still moves. Control-node capacitance and the external filter can cause a slow transient. A voltage difference that persists across different wait times supports static loading. If the difference vanishes, examine dynamic response. A closed control loop may keep steering the voltage. Record lock status and actual Vc so a standalone curve can be distinguished from closed-loop range.

Qualify the range the product can actually reach

When comparing 26 MHz VCTCXOs, keep the vendor's specified endpoint test and the minimum and maximum Vc attainable on the product. The latter should cover the relevant supply, temperature, and control path. Similar data-sheet tuning spans can yield different available correction if the existing DAC cannot reach the same terminal voltage with the substitute. Separate device conformance from board compatibility in the evidence.

If a filter resistor or buffer changes, repeat noise and settling checks. Reducing resistance can improve DC drop and also change filtering. Preserve the original pin voltage and frequency, then compare endpoints, steps, and settling with the same DAC commands. The next lot can be qualified against both curves and the actual electrical conditions.

For an endpoint fault, hold the DAC command constant and compare two known series resistances within allowed supply and control conditions. Record voltages on both sides and use the drop to estimate total downstream current. If the drop decreases with the lower-impedance drive and frequency returns to the measured Vc curve, the evidence for loading improves. If both setups flatten at the same voltage, examine DAC swing and board clamps. The resistor reading includes all downstream branches. Check the circuit before attributing protection or filter leakage to the oscillator input.

After changing range, check again whether connecting the meter shifts frequency.