Why can a 26 MHz oscillator change the ADF4351's 100 kHz tuning grid?

A laboratory synthesizer board adopts a 26 MHz active oscillator from another design. Firmware updates the reference value and requests 100 kHz tuning steps. Several frequencies land where expected, while others move to an adjacent setting. Lock reports success in both cases. That shows the loop reached a frequency allowed by its configuration. To establish the actual grid, calculate the phase-frequency detector rate, fractional modulus and final output divider.

Record reference, detector rate and output separately

The ADF4351 data sheet derives PFD rate from REFIN, reference doubling, the R divider and the reference divide-by-two bit. The RF output can be divided after the VCO. Suppose 26 MHz CMOS drives REFIN, with no doubling or divide-by-two and R set to one. The detector rate is 26 MHz. With a divide-by-one output, a 2450.0 MHz target also requires a 2450.0 MHz VCO. The fractional feedback multiplier is INT plus FRAC divided by MOD. If output division changes, calculate the required VCO target from the output and the divider first.

Dividing 2450.0 by 26 gives an integer of 94, accounting for 2444 MHz, plus a remainder of 6 MHz, or 3/13 of a PFD interval. For one point, FRAC 3 and MOD 13 represent that ratio. To use a 100 kHz VCO grid, MOD 260 divides 26 MHz into those steps. The same 2450.0 MHz point can use INT 94 and 60/260. The next point at 2450.1 MHz uses 61/260. A reduced fraction can represent one point correctly while changing the interpretation of a one-unit increase. If software automatically reduces the fraction, regenerate registers from each requested target.

With a divide-by-two output and the same grid, a 100 kHz VCO step appears as 50 kHz at the output. A 100 kHz external step then requires a 200 kHz VCO step or another applicable modulus. Check the VCO range and legal divider. A setting for one band cannot simply be carried to the others. Recompute the detector frequency whenever its doubler or divider changes.

Integer operation also changes the grid

Suppose the design selects integer operation to avoid some fractional spurs. With a 26 MHz reference and R of 13, the PFD is 2 MHz and INT 1225 produces 2450.0 MHz. With output division one, adjacent integers are 2 MHz apart. They cannot produce the next 100 kHz step at that setting. Changing R again also changes the detector frequency and calls for reviewing loop bandwidth, supported ratios and lock behavior. Measuring one clean point does not qualify the entire tuning table.

These calculations assume exactly 26 MHz. If the reference runs 2 ppm high and nothing else shifts the ideal locked ratio, an output near 2450 MHz likewise runs about 2 ppm high, or roughly 4.9 kHz. That is reference error rather than grid rounding. Use an independent traceable reference to check absolute frequency, and control measurement bandwidth separately when comparing noise or spurs.

Qualify a sequence of adjacent settings

Exercise neighboring settings, two on opposite sides of an integer boundary, and points before and after changing the output divider. Record actual REFIN, reference factors, INT, FRAC, MOD, lock wait and measured frequency. Confirm the programmed values have actually taken effect. For quick changes, capture command, lock indication and arrival within the required frequency window. Readback and the predicted setting can narrow a discrepancy more directly than inferring the oscillator from the RF output.

Record default startup and programmed operation separately. If the first point is correct but later spacing halves or doubles, inspect changes to the output divider before replacing the reference. Keep oscillator interface and frequency requirements with the sample. Board acceptance shows that the entire requested grid exists and transitions finish within the applicable deadline.

Before programming a long table, decode every row and retain its quantization error. Compare requested frequency, representable frequency and the value predicted from measured reference error. If rounding would make FRAC equal MOD, handle the carry within the permitted field range. Exercise adjacent points across an integer boundary and keep the actual register values.

If control and reference use different power domains, software may load valid settings before the source settles. Record when REFIN first meets its electrical and frequency requirements. Compare a complete cold start with steady tuning from an already established reference. Verify lock behavior on the actual hardware.