Why does a 27 MHz CMOS oscillator lose 100 mV at its high level under load?

Two 27 MHz CMOS oscillators show nearly rail-to-rail output unloaded. One has a lower high plateau on the board. Look for a pull resistor, termination, clamp, or other DC load. Datasheet output levels are often specified at defined source and sink currents. Capacitance mainly affects transition and settling behavior. A sustained resistive load can move the plateau. Two controlled loads can estimate the local sensitivity of output voltage to current.

Measure the actual source current

The Epson SG5032CAN brief includes 27 MHz and specifies high and low output levels at defined currents. Different voltage limits in the table have their own current conditions. Match the complete ordering item and fixture. A clean unloaded waveform does not replace the loaded check. Verify actual pin voltage and the direction and reference for each test load.

Suppose two actual source currents are 2.0 and 4.0 mA. The respective high levels are 3.16 and 3.06 V. The 0.10 V change over 2.0 mA gives a local effective slope of about 50 Ω. This describes the sample between these points, at the given supply and temperature. It can be nonlinear and differ by state. It is not a transmission-line termination recommendation. With a resistor to ground, 3.06 V across 765 Ω gives 4.0 mA. Use the actual voltage across the resistor rather than nominal supply.

Choose a settled part of the waveform

Measure light load, specified load, then light load again. Use the prescribed plane and a suitable probe. A 27 MHz cycle is about 37.04 ns. An approximately even waveform leaves about eighteen nanoseconds per state, but the usable plateau depends on loading and edges. Measure a valid stable window, keeping the complete wave for review of overshoot and ringing. If there is no clear plateau, use the applicable alternative procedure.

Low-state current usually needs the opposite load direction. Use a permitted method to sink current into the output and measure its low plateau. For a resistor to a reference rail, calculate current using the actual rail-to-output voltage. Check both states for allowable limits. Dynamic load and reflection should be measured separately at receiver thresholds. A compliant DC plateau does not determine pulse width or settling.

Compare the output and receiver planes

If the output repeats at 3.06 V but the receiver plateaus at 2.8 V, inspect series resistance and any DC return path. Distinguish DC drop from reflection. Measure actual receiver level if the system needs another 0.2 V of margin. Record high and low voltages, test currents, both planes, rail voltage, load, and temperature for old and new samples. That supports a decision about the load or the replacement.

When the light-load endpoint moves by an amount comparable to the observed drop, check meter offset, supply, and heating. Measure at the regulator and package to locate any supply movement. Use the local slope only after repeatability is established. Measure separately outside the verified range.

The receiver can change pulls during startup. If a low plateau occurs only before firmware configures the input, align that event with the waveform. Repeat after the system enters its normal mode, keeping transient and steady conditions in the record. Restore equivalent control settings before comparing oscillators.

At an actual 3.3 V and with the corresponding ordering conditions, the brief's ninety- and ten-percent limits are at least 2.97 V high and at most 0.33 V low at 4 mA source and sink respectively. The illustrative 3.06 V at 4 mA only addresses the high-state check. If two suppliers quote similar levels at different currents, verify the common board loading and receiver thresholds as well as the separate datasheet conditions.

Record the measured resistance and connection. For a borderline result, repeat with an equivalent fixture and verify the actual branch current at the measured plateau before comparing oscillators.