An acquisition device has a running 27 MHz passive crystal beside its ADV7611. When the HDMI source is unplugged, the FPGA still measures LLC and the screen does not immediately go blank. A driver that treats any pixel clock as proof of source video can label free-run output as a received signal. The reference manual treats input status and local free run separately. Define what the product should do while disconnected, then choose evidence that actually proves the intended state.
Identify the input and output clocks separately
The clock on the HDMI cable belongs to the upstream link. LLC carries output timing from the ADV7611 to the receiver. Depending on the data path it can be the pixel clock or a divided version. The crystal supports the local timing path. Record these as distinct signals. An LLC after disconnection does not demonstrate that the upstream TMDS clock remains. Supplying predictable output under missing input is a purpose of free run.
The manual describes two HDMI free-run conditions. Mode 0 applies when the selected input does not have a detectable TMDS clock, such as during a cable disconnect. Mode 1 can also enter free run when the detected format differs from the programmed expectation. A separate enable applies. A live cable and a present input clock can therefore coincide with local output. Test disconnection and source-format mismatch separately.
Match the crystal selection and output format
ADI lists 27 MHz as a supported crystal frequency and gives it selection code zero. The listed default is 28.63636 MHz. Read back the selection on a board fitted with a 27 MHz passive crystal. Match the fitted part and schematic to the startup script, especially if the script came from another evaluation setup. The ratio between those two crystal frequencies is not a general predictor of every output mode with a wrong selection.
Suppose an acceptance case targets progressive 1080-line video at 60 frames per second. With 2,200 total pixel slots per line and 1,125 total lines per frame, including blanking, the rate is 2200 × 1125 × 60 = 148.5 MHz. One frame takes about 16.67 ms. Expect about 148.5 MHz at LLC only if the selected path forwards the undivided pixel clock. Apply the documented division for other paths. The example follows from the complete output timing.
Compare identifiable source video and local output
Use a video source with a changing counter or unmistakable test patch. Verify the sequence and input lock, and retain input status and output sync in one record. Unplug the cable, then observe LLC, vertical sync and data enable for several frames while reading input and free-run status. Repeating a cached frame and generating a new local stream can look similar on a screen. Check data activity and whether the source pattern actually keeps changing. After reconnecting, note when source content returns.
Keep the cable connected for a second comparison. Change to a valid source format that differs from the expectation, then exercise the two documented free-run modes. Confirm the source format and register settings. One format accepted by both cases will not show the distinction. Use the observations to decide whether capture software records signal loss, retains a local placeholder or excludes those frames. Save captures before the change, at the transition and after re-lock.
Also test a cold start with no HDMI source. Let the actual production initialization finish, read back clock selection and free-run settings, then measure the output format. Compare with unplugging an input that was already working. If only the unplug event produces the expected output, part of the sequence may depend on a previously established input.
Add host event logs when measuring reconnect behavior. For example, a receiver that unmutes after three vertical sync events uses roughly 50 ms at 60 frames per second. That time comes from the receiver's policy and frame count. Continuous output timing does not prove that newly received content has reached the display. Record input lock, timestamp changes and the first valid content together. If a buffer still needs to drain, define which frame is first eligible for recording. Display buffering, input lock and local crystal startup can then be timed separately.
List the 27 MHz passive crystal, frequency selection, local format and input detection criteria on the sample acceptance record. The local clock can sustain useful output while the source is missing. Input state and identifiable content prove when the output belongs to the source. Record disconnect, reconnect and format mismatch, so a later revision can repeat the same tests.