An ADS1675 acquisition board uses a 32 MHz active crystal oscillator at CLK. The low-speed mode works. At four million samples per second, the original controller still tries to drive the shift clock. It occasionally sees a word and otherwise reads zeros. The reference still measures 32 MHz. First check which device drives SCLK in each data rate mode and when a pin that was an input becomes an output.
The converter drives its high-speed shift clock
At low data rates, DRATE values 000 through 011 allow a CMOS interface. In CMOS mode SCLK_SEL can select an internal or external shift clock. A low-speed LVDS interface uses the ADS1675's internal SCLK. The high-speed choices, DRATE values 100 and 101, require high-speed LVDS. The device ignores the two pin settings that select interface type and clock direction at lower speeds, though the pins still require defined levels. A controller output carried over from low-speed CMOS operation can contend with the ADC output.
In high-speed mode the ADC PLL multiplies CLK by three. With a 32 MHz active crystal oscillator, SCLK is nominally 96 MHz and its period is about 10.417 nanoseconds. At four million samples per second, the 250-nanosecond sample interval contains 24 nominal shift-clock periods. The high-speed output has 23 bits of resolution. The 24th bit stays low, so use the vendor timing and data-format diagrams when interpreting the word. A controller running at 32 MHz could supply only eight periods in 250 nanoseconds. It would also be driving the wrong end of the link. Generating a separate 96 MHz signal does not replace the data clock sent by the ADC.
One reference can serve both modes, but their receiver requirements differ. A board built solely for low-speed CMOS needs an appropriate differential receiver, termination, and a way to isolate the old clock driver. Observe the signal at the ADC and receiver to locate interconnect and loading problems.
The first DRDY can mark PLL lock
TI specifies that the PLL needs time to settle after power-up in high-speed mode, after a reference frequency change, or after a transition from low speed to high speed. DOUT and SCLK are held low during lock acquisition. When the PLL locks, the ADC supplies continuous triple-frequency SCLK and gives a DRDY pulse regardless of the state of START. Discard the data associated with this pulse and toggle START before capturing normal data as recommended. Switching between high-speed modes does not require relocking the PLL, although the new conversion settings still need to be applied correctly.
The normal data-ready pulse is nominally three SCLK periods in the high-speed description. At 96 MHz, that is about 31.25 nanoseconds. A slow GPIO polling loop can miss it. Record START, DRDY, SCLK, and DOUT to relate the first continuous clock to the lock notification, then locate the first complete conversion after restarting. PLL availability and valid filtered measurement data are separate events.
Qualify each board interface
Start with a stable analog input within range. Verify CLK levels, duty cycle, and edges against the data sheet, followed by shift clock direction, rate, differential swing, and termination. Use the published shift timing to select capture edges, and verify the DRDY relationship and the first bit of DOUT. Small positive and negative inputs help confirm signed decoding. Test other levels and confirm the fixed low bit remains in the documented position.
For boards using a 32 MHz active oscillator, retain CLK amplitude, power sequence, DRATE, SCLK source, and the first valid sample position. Test both a low-to-high speed transition and a cold start directly into high-speed operation. If the problem is limited to the first DRDY, review initialization. If words keep failing, look at receiver timing. Qualify the reference oscillator's electrical and timing requirements together with a separate check of the board's change in shift-clock ownership.
Another symptom can distract from the transition: DRDY is active, while SCLK and DOUT appear absent. The data sheet says inactive CS three-states DOUT and internally generated SCLK, while DRDY remains active. During PLL acquisition the outputs are instead held low. Capture CS together with the three differential signals and verify selection in the intended read window. When multiple devices share the bus, check that the next device begins driving only after release. Captures next to the ADC and at the host connector can also help to distinguish selection from an interconnect problem.
A self-test that reads only an input near zero may miss a misplaced sign bit. Apply in-range positive and negative inputs and retain the raw words with the rate and capture format. Inspect them before applying any legacy scaling. Confirm that comparisons across the rate change begin at the first newly valid sample.
Tie the rate setting to the first accepted frame in the test log. Stop consuming the old conversion results when changing the mode pins, restart conversions as directed by the data sheet, and then resume recording. A host buffer can retain an old nonzero word before the new valid-data marker. Correlate the first logged word with the chip select and data-ready edges.