A repair note says “33 MHz, 20 pF” and shows a low metal crystal can close to the board. Two ECS part numbers match those entries, ECS-330-20-3X-EN-TR and ECS-330-20-46X. In a top-down photo, either could look like the part on the board. Turn the board over and trace the two connections. One part needs surface lands under its terminals. The other needs plated holes for its leads. Establishing how the board is built can narrow the order even before the original bill of materials turns up. The following calculations illustrate how to check a board against the drawings.
Identify the copper and holes at the original location
For a surface-mount location. The 3X is from the CSM-3X family. Its two surface-mount terminals are electrically interchangeable according to the package drawing. The recommended layout uses two 3.5 × 1.2 mm lands with a 2.0 mm gap, giving 5.5 mm between land centers and 9.0 mm between the outer edges. Measure the actual copper in the PCB file, then check the mask openings and stencil. Solder on an old board can hide the copper edges. A location with only these surface lands lacks the holes and underside joints needed to assemble the 46X as a through-hole part. ECS CSM-3X package, land pattern and reflow data.
For a through-hole location. The 46X belongs to the HC-46X family. Its drawing shows 2.5 ± 0.2 mm between lead centers, a lead diameter of 0.34 ± 0.02 mm and a typical lead extension of 7.5 mm. Look for the two soldered leads on the underside and use the board drill file or fabrication drawing to check finished hole diameter and pitch. A nearby via can resemble a lead hole in a photo. If the board files are unavailable, follow the copper connections to verify which holes actually reach the oscillator pins. Check underside space for solder joints and trimmed leads before accepting a through-hole replacement. ECS HC-46X package and lead drawing.
Calculate clearances from the drawing
The 3X ordering page lists a 7.00 × 4.10 mm package size. The series drawing has distinct longitudinal dimensions labeled 7.0 ± 0.2 mm and 7.6 ± 0.5 mm. For the outer clearance check, use the larger outline, with a maximum length of 8.1 mm, width of 4.1 mm and height of 2.3 mm. Use the 9.0 mm outer land span to check the layout separately. With a 7.8 mm slot between adjacent structures, the package-size field looks promising, but the largest outline exceeds the slot by 0.3 mm. Recheck against the controlled drawing for the ordered item or revise the available space before approving the fit.
The HC-46X drawing gives maximum outer dimensions of 6.8 × 4.0 × 1.8 mm for the package above the leads. Suppose the usable height from board surface to enclosure is 2.2 mm. After allowing for the 1.8 mm package, 0.4 mm remains for board-to-package standoff, board bow and enclosure tolerance. Check the metal base clearance and the space beneath the board as well. A part that fits in plan view can still interfere with the housing or nearby copper after soldering. ECS CSM-3X outline and suggested land drawings, ECS HC-46X outline drawing.
For a simple insertion check, suppose both finished holes are 0.50 mm at minimum diameter and exactly 2.50 mm apart. With leads at the maximum diameter of 0.36 mm, the radial clearance at each hole is (0.50 − 0.36) ÷ 2 = 0.07 mm. If the part has a 2.70 mm lead pitch, centering the body makes each lead miss its hole center by 0.10 mm. This pair of holes cannot guarantee insertion with straight leads, even before allowing for hole-position error, plating tolerance or lead form. Confirm the finished hole diameter and tolerances with fabrication and assembly. A single sample that drops in confirms the fit of that particular part and board.
Check temperature, load and startup under their own conditions
Both exact ordering pages list 33 MHz, a 20 pF load, ±30 ppm initial tolerance and ±50 ppm stability. The family data sheets specify fundamental-mode operation, ±30 ppm at +25 °C and a 40 Ω maximum ESR in the 30 to 40 MHz band that includes 33 MHz. Both also list a 7 pF maximum shunt capacitance, a 100 µW maximum drive level and ±5 ppm first-year aging at +25 ± 3 °C. These limits make a useful starting point. Actual values vary from part to part, and one room-temperature frequency reading cannot verify the limits. ECS 3X electrical conditions, ECS 46X electrical conditions.
The operating ranges differ by ordering code. ECS lists −40 to +85 °C for ECS-330-20-3X-EN-TR and −10 to +70 °C for ECS-330-20-46X. For equipment that must start at −20 °C, the cited 46X is already outside its rated operating range. The wider-temperature 3X still needs compatible surface lands. The standard rows in the two family sheets state the stability condition at −10 to +70 °C. For an explicit ±50 ppm requirement over −40 to +85 °C, ask for the controlled specification for the exact EN part, including the stability interval and test conditions. Check storage ratings separately. ECS-330-20-3X-EN-TR ordering page, ECS-330-20-46X ordering page.
For a Pierce oscillator with a capacitor to ground at each crystal pin, a first estimate is CL ≈ C1 × C2 / (C1 + C2) + Cs. Here Cs is an equivalent stray-capacitance estimate for the pins, traces and connections. Suppose it is 3 pF on a particular board. Two 34 pF capacitors yield an estimated load of 20 pF, while two 20 pF capacitors yield 13 pF. If an adapter adds 2 pF of effective stray capacitance and the 34 pF capacitors stay in place, the estimate becomes 22 pF. Use crystal pullability data or measurement to find the resulting frequency shift. When the host has programmable internal capacitors, use its actual pin model and configuration. STMicroelectronics AN2867 on load capacitance and startup verification.
At 33 MHz, 1 ppm is 33 Hz, so ±30 ppm represents ±990 Hz and ±50 ppm represents ±1,650 Hz. If the controlled specifications allow the two error terms to be budgeted separately, their illustrative worst-case sum is ±2,640 Hz before board load error and aging. Use the same frequency reference, temperature, load and drive conditions to compare parts, and record the test point and any clock division. If a change in package, layout or adapter changes the circuit parasitics, check startup margin, crystal drive and startup time as well as steady-state frequency. A room-temperature power-up covers one condition. Production qualification should cover the intended temperature and supply corners.
Make the assembly constraints part of the order
For a board that cannot be changed, send its revision, the original full part number, front and back photos, verified land or hole geometry, available height, operating range and stability requirement. Ask the supplier to identify the complete part number, controlled drawing, lot and packing method. ECS lists tape and reel for the 3X TR configuration and bulk packing for the 46X family. Confirm the applicable assembly profile for the actual part, whether the work is hand repair, surface-mount production or through-hole assembly.
If a board change is in scope, check the footprint and enclosure first, then qualify frequency, startup and drive on the assembled board over the intended temperature and supply range. An adapter, formed leads or wire connections can be evaluated on an engineering prototype, with the actual wiring, mechanical support and parasitics included in the test. For an unchanged through-hole board required to operate below −10 °C, these two exact parts leave a gap. Look for an orderable through-hole part with matching geometry and a controlled specification covering the required temperature, or have the board designer qualify a surface-mount revision.