A 40 MHz crystal is a few hundred hertz fast. Why can a CC1200 carrier be several kilohertz off?

A CC1200 board uses a 40 MHz passive crystal. Under controlled test conditions the offset register shows a few dozen counts, yet the software displays tens or hundreds of kilohertz. An opposite correction does not behave as expected. Keep three quantities separate: reference frequency error, RF carrier error, and the conversion scale at the local oscillator. Using the crystal frequency alone can produce the wrong magnitude and sign.

Calculate hertz per count for the selected RF band

Texas Instruments defines an internal VCO derived from the crystal, followed by the local oscillator divider for the selected RF band. FREQOFF is a signed sixteen-bit word. Increasing it by one count changes VCO frequency by crystal frequency divided by two to the eighteenth power. Divide again by the local oscillator divisor for the RF change. The main frequency word has a different scale. Log the band, divider, main tuning word, and FREQOFF before comparing.

In the 820 to 960 MHz example, the divider is four. Divide the 40 MHz reference by two to the eighteenth and then by four: approximately 38.15 hertz per offset count. If two register bytes form hexadecimal FF9C, signed decoding gives minus one hundred. Relative to zero offset, that lowers the RF setting by about 3,815 hertz. Unsigned decoding interprets the same word as 65,436 and would report approximately plus 2.5 megahertz. This is a useful case to replay when a user interface reports an unusually large change.

For a divider of eight, the same illustration gives 19.07 hertz per count, or roughly minus 1,907 hertz for minus one hundred. This demonstrates the divider ratio. Actual tests in another band require a board, RF path, and load suitable for that band. A programmed slope that halves with the change of divider does not show a sudden shift in the passive crystal.

Apply a known correction on the bench

Measure a repeatable RF output with a calibrated instrument in a conducted or shielded setup. Record the instrument reference and avoid accidentally referencing the instrument to the DUT oscillator. Establish a baseline in a verified operating configuration. Apply small positive and negative offset changes on the engineering board and follow the part's required state sequence. Check carrier direction and magnitude with the external measurement. Log both the effective configuration and its state transition, because the user interface may display a pending write.

TI says the estimate uses the same format as the programmed offset. It can be accumulated manually or handled by the automatic frequency correction strobe. The strobe takes effect on the next entry into an active transmit or receive state. State whether correction is enabled and keep separate observations before the command and after the transition. Receiving a packet provides a relative error. The other transmitter also contributes, so crystal acceptance needs an independent known signal or direct carrier reference.

Check reference scaling with the 40 MHz passive crystal. If it is ten parts per million fast, the reference error is four hundred hertz. With tuning and division fixed, a 915 MHz carrier gains the same ten parts per million, approximately 9,150 hertz. Measuring a few carrier settings can support this diagnosis. A proportional hertz deviation at different carriers indicates a common reference contribution. A constant offset in hertz suggests further checks on receiver offset, analyzer reference, and software correction.

Apply plus and minus one hundred counts from the same zero-offset baseline rather than accumulating them. Subtract the two measured frequencies for each comparison and check the expected movement of about 3,815 hertz. This separates programmed step size from the original oscillator offset. If positive and negative magnitudes differ, check instrument range, RF configuration, and register state. If only the software display is wrong on a negative correction, also check byte order.

Retain three independent records for acceptance

Log when the estimate was read. Conduct reception and baseline RF measurements in separate runs so an estimate retained from a prior packet is not mistaken for a new observation. With a known input, repeat at one temperature and log valid packets and states. Where drift over temperature is the issue, test the applicable operating range. Compare measured error with available correction margin before changing the incoming limit or replacing the crystal.

Keep actual RF frequency, measured crystal or verified buffered reference, and the signed settings and divider that applied. If the crystal is removed for a loaded frequency measurement, use its specified load. Do not replace the in-circuit result with that isolated measurement. Compare substitutions at the same temperature and reference planes. If the programmed slope is right but the uncorrected offset moves, check crystal temperature and loading. Fix decoding or update timing before judging a lot if those explain the discrepancy.