A 40 MHz crystal fails an interim damp-heat check. Was condensation introduced when the chamber opened?

A lot of 40 MHz passive crystals is removed during a damp-heat test, measured for a few minutes, and returned. The last group has higher resistance, with the strongest effect near the door. The formal exposure calls for steady noncondensing conditions. Opening and reloading may have introduced condensation. Inspect local dew point and case temperature before deciding whether the record answers the original reliability question. Brief condensation may not leave visible droplets.

Compare dew point and specimen temperature

NDK's guidance on damp-heat exposure warns that opening the chamber or removing specimens mid-test can introduce condensation. A displayed chamber value comes from a control point. Rear airflow, a metal fixture, and the specimen housing can respond differently when the door opens. Record temperatures fast enough and measure humidity where it represents the specimen environment. A stable setpoint saved before opening cannot document the transition.

Suppose air near one chamber position is 40 degrees Celsius and 85 percent relative humidity. Applying the US National Weather Service vapor-pressure and dew-point relationships gives about 37.0 degrees dew point. A specimen returned at an actual case temperature of 35.0 degrees can condense moisture if it encounters that same air. Its case is about two degrees below dew point. The margin can disappear after several minutes of recovery. These are illustrative conditions, not a product test rating.

Opening the door can change the air's moisture as well as its temperature. Do not assume a fixed 37-degree dew point everywhere. Log temperature and humidity near the door and specimens, and monitor the first returned specimen or a representative witness. Compare its temperature with local dew point on the same timeline. Include sensor lag and attachment uncertainty. A narrow separation may support only a risk interval, even if the display shows a decimal place.

Reproduce the permitted exposure sequence

Check the governing standard and project for allowed interim removal, duration, and recovery. If intermediate data are needed, a supported in-chamber measurement path or a separate witness lot can avoid repeated removal of pieces meant for uninterrupted exposure. An in-chamber connection needs appropriate installation, drive, and electrical conditions. Chamber conditions can also affect fixture contacts.

Where door opening is permitted, rehearse with an empty fixture and monitoring specimens reserved for diagnosis. Record door time, tray position, time outside, and temperature at re-entry. Follow the approved heating and humidity sequence. NDK's example explains why heating before applying humidity matters for a noncondensing test. A fixed number of minutes cannot replace evidence that the samples reached the needed temperature.

Separate device change from fixture change

After specified recovery and stabilization, test a reference part and empty test path before retesting suspect 40 MHz passive crystals. Record frequency and resonance resistance with the specified drive and load as well as any failure to start. A wet fixture, contamination, or contact effect can affect low-drive tests. Recovery of the measurements shows a reversible contribution. It does not establish valid original exposure. Retain parts and records for the supplier if resistance remains abnormal.

Keep a comparison group with uninterrupted exposure at equivalent positions. If only the remove-and-return group changes, that supports a transfer effect. If both groups fail, check actual local exposure and specimens. Where condensation is intentionally required, use its specified sequence and limits. Accidental handling exposure is unsuitable as a substitute for that protocol.

Include the affected interval in acceptance records

Compare original and replacement 40 MHz passive crystals under the same permitted exposure, placement, measurement, and recovery. Keep setpoints and durations, interim operations, the closest approach of case temperature to dew point, fixture baseline, frequency, and resistance. If an unplanned excursion occurs, apply the agreed treatment for test validity and repeat as needed. An endpoint report alone can turn a handling difference into a lot decision.

List each interval in which case temperature fell below dew point, with the trays actually present. A logger recording once per minute can completely miss a five-second door event. An absent record does not rule it out. Qualify sensor response with a transfer of the same duration and verify that air and specimen data share a timeline. Track tray location so readings from unrelated positions do not form an impossible exposure curve.

If the contract calls for intermediate sampling, arrange witness specimens in advance at equivalent mounting conditions and use a procedure that preserves the main lot's required exposure. Send the operation log with the report.