A 40 MHz active oscillator drives a divider that supplies the external synchronization signal for a TPS546D24A power converter. The rail drops briefly on some wakeups, yet a frequency counter at the oscillator still reads 40 MHz. The divided signal can stop even if its source does not. The power converter also treats a lost sync differently in a standalone device and in a multiphase stack.
Trace the clock to the SYNC pin
Mark the oscillator output, the divider output and the receiving SYNC pin. A long counter gate measures the source’s average frequency. Trigger on a long interval at SYNC and capture the two upstream nodes, divider reset and power-good state if available. Check the reference level and loading at every interface, including any translating buffer.
The converter’s SYNC pin can be an input or an output. TI describes separate modes for a standalone circuit, a stack master and a stack slave. Confirm the actual direction after any startup auto-detection. Never compare results by wiring two active outputs together. The circuit must be configured for the intended direction before the input waveform can be meaningfully evaluated.
Calculate the expected period and capture interruptions
An 80:1 division of 40 MHz gives 500 kHz and a nominal 2 µs period. Suppose the free-running switching-frequency setting is 550 kHz. The electrical table’s ±20% sync range around that setting corresponds to 440–660 kHz. The example frequency is inside that range, subject to input voltage, pulse width and the other conditions in the data sheet. A +20 ppm reference error contributes only +10 Hz after division. Improving static ppm cannot recover missing pulses.
TI describes loss detection when input pulses are missed for two cycles or the stated low-frequency condition occurs. Two 500 kHz nominal periods total 4 µs. Use that as an illustration for choosing a capture time scale, not a guaranteed output-drop delay. Measure SYNC, the power stage and the rail together. TI describes standalone operation near half the nominal switching rate after a lost sync, while a multiphase stack shuts down until synchronization is restored.
The same example checks pulse width. A six-percent high pulse in a 2 µs cycle lasts only 120 ns, 80 ns short of a 200 ns input-width design requirement. With an illustrative 50% duty cycle, the high and low intervals would each be 1 µs. Both may read 500 kHz on a frequency counter. Compare the receiver levels and pulse widths, including the first pulses after wake, which may be truncated.
Test source continuity separately from mode selection
On a controlled, appropriately loaded fixture, capture a good wakeup first. Repeat the failing reset or mode transition with the same board, wiring and loading. If the gap appears at the divider while the 40 MHz source is continuous, check when the divider is reloaded, gated and released. If the divider output continues but the receiving pin misses edges, check the translating buffer’s power and enable sequence. Follow the vendor’s evaluation conditions for power-stage tests.
If the receiving SYNC waveform is steady but the converter behaves as if free-running, read back the applied frequency setting and check when the external waveform became valid relative to detection at startup. The electrical table specifies a pulse-width condition. Measure the pulse and levels at the actual receiving pin, since a divider output can look correct while a later stage changes the edge. Verify the direction and acceptance before drawing conclusions about the load.
If a new oscillator happens to fix the problem, repeat with the original part. Capture source startup, the first sustained valid SYNC pulses and the load’s power-up time on the same system. This distinguishes a repeatable oscillator startup property from a coincidental change in supply and reset order.
Put incoming parts and system operation on separate acceptance rows
For a 40 MHz active oscillator, quote the full identifier, output type, voltage, ready time and enable behavior under load. For a different circuit using a 40 MHz passive crystal, establish when the controller oscillator and divided output become usable. Record whether sync can pause during standby or restart and whether the converter is standalone or stacked. Keep the oscillator acceptance and the downstream sync requirement together in the handoff. This distinguishes a clock component issue from an interruption in its delivery.