A capacitive board reads normally near its target, but moving the target farther away brings outliers and sometimes error indications. The FDC2214 continues to receive a steady clock from the 40 MHz oscillator at CLKIN. Test the input deglitch setting separately. The LC oscillation changes with effective sensor capacitance, and that is the signal the filter must pass. Change just the filter setting and see whether it recovers the faulty region of a sweep with known capacitance.
Locate the two frequencies
TI routes the external controller clock through CLKIN and the sensor through the input pair for its channel. With the external reference selected, the 40 MHz oscillator provides the measurement timebase. The input deglitch filter rejects ringing and interference in the sensor path. Choose the lowest bandwidth that exceeds the highest sensor frequency. The nominal options in the data sheet include 1, 3.3, 10, and 33 MHz. The allowable sensor input frequency is a separate specification. A 33 MHz filter option does not make 33 MHz a supported sensor frequency.
Save the board configuration and substitute a test inductor and measured capacitors on the same input. Keep the branches short and account for fixture, wiring, and probe capacitance. Retest the real electrode and cable in the enclosure as well, since position, humidity, and nearby metal can change the effective capacitance. Keep the filter, drive current, conversion counts, and channel order independent when identifying a cause.
Bracket the nominal filter setting with two capacitors
With a 22 µH inductor and total effective capacitance of 125 pF, the ideal LC frequency is about 3.035 MHz. At 90 pF it is about 3.577 MHz. The values straddle the nominal 3.3 MHz filter setting. The same ideal expression gives about 105.7 pF at 3.3 MHz. Use smaller steps near that part of the sweep. The calculated capacitance is a convenient test point, not a guaranteed device trip threshold.
Hold the external 40 MHz oscillator, reference and sensor dividers, drive, and sample mode constant. Change the register while the device is asleep, following the data sheet. Compare 3.3 MHz and 10 MHz after allowing the conversions to settle, using equal record lengths. Capture the actual frequency and amplitude at the sensor, along with raw codes, status, number of valid results, and spread. A probe can lower the frequency enough to put a marginal point back below the filter setting. If attaching it cures the fault, use lower-loading observation and compare the unprobed and probed code records.
Determine which part of the chain recovers
If the sensor continues to oscillate while a change from 125 pF to 90 pF introduces bad points at 3.3 MHz, and the 10 MHz setting clears them with the same sensor waveform, the filter setting is implicated. Reinstall the larger capacitance and verify that it restores operation at the lower setting. If every setting fails at the same position and the analog oscillation weakens or stops, check the resonator loop, losses, and drive. Reading a digital code does not establish adequate sensor amplitude. Check the expected amplitude convention and the probe loading.
Next, run the 10 MHz setting with the real sources of interference present. Operate the adjacent motor or switching supply as in service, move the target repeatedly into and out of the far end of travel, and log outliers with the enclosure assembled. If the fixture passes but the wiring harness brings the fault back, examine grounding, shielding, routing, and input conditioning. More filter bandwidth admitting the desired sensor frequency can also admit more interference.
Distinguish filter recovery from insufficient settling after a channel change. If the error is confined to the first sample and extra settling restores every setting, review settling and the new-data indication separately. If a single channel in continuous operation still fails only at the low-capacitance end, sweep again on the wider setting. Save single-channel and scanned runs separately to reveal whether there are two mechanisms.
For a repeatable full scan, also use an electrode specimen with a fixed position and a reproducibly inserted dielectric. If the wider filter appears to yield more samples, verify the fresh-data status first so faster polling does not look like recovery. Apply the same invalid-code rule to both runs and retain the fraction discarded. A passing station must clear the original fault without trading missing codes for an apparently smoother trace.
On a production-style board, measure both settings and then return to the first one. The return run helps exclude slow electrode motion or temperature changes from handling. Before comparing two boards, check their effective capacitance and inductor tolerances at the same target position. Mechanical marks alone can align different frequency regions. Report the highest frequency and the lowest amplitude separately because they may occur at different positions.
Record the highest sensor frequency covered at qualification
Keep the test capacitors, inductor, measured sensor frequency, amplitude, filter setting, and limits on missing or incorrect results together. Cover the specified mechanical, harness, and temperature variation. Retain the CLKIN waveforms for both sources. If the original and candidate 40 MHz oscillators both provide a compliant reference while failures track filter setting and sensor frequency, revise the filter setting or interference qualification. Compare the oscillators further if the fault still tracks reference timing or frequency with sensor range and filter settings held fixed.