Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Why does MAX98357A play the wrong TDM channel on a board with a 40 MHz reference?

A multi-speaker terminal shares one TDM audio bus and uses a 40 MHz active oscillator as the host reference. After replacing an amplifier module, the speaker on the right works but plays another channel's prompts. Check the frame clock count, sync waveform and actual slot straps. The amplifier consumes the selected portion of the common data stream. It can play normally from the wrong slot when that slot contains audio.

Count clocks per frame and identify the selected slot

The manufacturer says the MAX98357A recognizes TDM from a short pulse on the frame sync input. A 50 percent left/right clock identifies the relevant stereo serial format. Two signals at 48 kHz can therefore represent different framing. TDM has eight slots, with 128 clocks at sixteen bits per slot or 256 at thirty-two bits. At 48 kHz, bit clocks are 6.144 MHz and 12.288 MHz, respectively. Trigger on frame sync and count bit clocks between successive pulses, then check the first data bit against the relevant waveform.

The 40 MHz active oscillator is the host reference in this example. If the audio peripheral derives its clocks from that source, use the host's supported audio clock route. Forty divided by 12.288 is not an integer, so a plain integer divider cannot produce that rate exactly. The host may instead use a separate audio reference or another clock branch. Measured BCLK, frame sync and data establish how the amplifier reads each frame.

Check the exact amplifier suffix before selecting a timing diagram. In TDM the A device samples on rising BCLK edges, while the B device uses falling edges. Similar packages and markings do not justify assuming that the devices sample the same way. If audio is recognizable but distorted, inspect data around the specified capture edge, then check bit position relative to frame sync. Slot selection, bit alignment and setup timing can be tested independently.

The gain pin also participates in slot selection

The TDM strap table uses SD_MODE and GAIN_SLOT together. With GAIN_SLOT grounded, direct SD_MODE high selects slot zero, while pulling it up through the specified large resistor selects slot five. A direct link does not substitute for that resistor. In a different audio format that same gain pin controls gain. Check the active bus mode before carrying over the population from a stereo module.

The manufacturer shows an internal pull-down of about 100 kΩ on SD_MODE. With a 1.8 V pull-up supply and a 300 kΩ resistor, nominal division gives about 0.45 V. At 3.3 V the manufacturer's large-resistor example is 634 kΩ, again giving about 0.45 V. Keeping 300 kΩ with a 3.3 V pull-up would give about 0.825 V. The arithmetic ignores spread in the internal resistance and board leakage. With a new logic rail, confirm the manufacturer strap table, thresholds and actual voltage instead of inspecting resistor markings alone.

Isolate one slot at a time during acceptance

Play a known moderate signal in only the intended slot, leaving the others zero. Then move it to an adjacent slot while preserving clocks and strap settings. Listen for the one that plays and compare it with the actual frame decode. Document whether channel labels start at zero. If both tests produce sound, check whether the host duplicated data or the interface entered a different format. Other audio formats do not necessarily use the same channel selection signals in the same way.

Slot length also checks an analyzer's labels. At 48 kHz a frame lasts about 20.833 µs and each of eight equal slots lasts about 2.604 µs. The slot-five boundary is therefore about 13.021 µs after the slot-zero boundary. Measure the exact alignment of frame sync and the first data bit against the manufacturer's timing diagram. This calculation does not remove the need to check the one-clock alignment. A decoder configured for two stereo half-frames cannot identify the position of one thirty-two-bit word among eight slots. You can also test the other supported word width and count the actual frame clocks to verify that software applied the new format.

In TDM the gain is fixed at 12 dB and the pin participates in slot selection. A production change copied from an older gain option can move the selected slot. Keep the amplifier suffix, logic pull-up voltage, the two strap settings and intended slot with the assembly record. Save both the original module's and the replacement's results and check the harness power and return. If the correct slot remains selected and only audible output level changes, inspect load and power rather than continuing to alter routing.

Check the 40 MHz active oscillator output and host clock path as part of sample approval. For the complete board, retain the sync waveform, clocks per frame, capture edge, strap state and single-slot result. The same test also compares a board before and after an oscillator change. Identical audio in two slots can hide a mapping mistake. An unambiguous test tone correlated with the receiving pins verifies which slot the amplifier actually uses.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.