A legacy USB capture board can label four frequencies on one clock diagram. A 40 MHz active oscillator supplies only the reference to TUSB1310A. The PHY supplies a 250 MHz PIPE clock and a 60 MHz ULPI clock, plus a CLKOUT associated with a particular power state. If USB 2.0 enumeration is the only test after replacing the oscillator, a required SuperSpeed path can still be broken. Label each node by role and by the operating condition in which a signal should appear.
Order by the input reference and measure bus timing at the PHY outputs
TI specifies driving XI and leaving XO open for an external source. A build fitted with a 40 MHz oscillator also needs the matching sampled REFCLKSEL setting. The USB link speed reported by a host does not identify the oscillator. Check the documented assembly selection, the circuit, and the waveform at XI. A substitute needs the relevant input swing, edges, frequency tolerance, and jitter verification under the manufacturer's conditions. A nominal 40 MHz marking is only one part of that qualification.
The data sheet describes a 16-bit PIPE operating at 250 MHz and an eight-bit ULPI at 60 MHz. At one parallel word per cycle, these supply four billion and 480 million bit positions per second respectively. The periods are 4 ns and about 16.67 ns, compared with 25 ns at the external reference. These are bus timing and width calculations. They do not give application throughput, which depends on link encoding and protocol behavior. The 60 MHz record does not demonstrate correct sampling on a separate 4 ns interface.
Interpret a quiet clock in the correct power state
The clock-distribution section says 120 MHz CLKOUT is available only in USB U3 for the associated low-power path. Its period is about 8.33 ns. A quiet CLKOUT in another state cannot establish a failed reference oscillator. The ULPI pin description also says its clock is not driven in low power. Record the actual state when taking each measurement so that a state-dependent clock is not tested as always on.
If transfers fail after resuming activity, record the control state, interface clock, and PHY_STATUS together. TI describes initial startup separately from returning to the active state. Start the latter measurement when the controller requests the documented state, then observe the PHY's readiness indication. A toggling clock, readiness to accept transactions, and successful traffic are separate observations. Capture a recognizable request and response, as well as clock frequency, during the first transaction after recovery.
Use the negotiated mode to choose the path to test
Begin with a stable supply and check the proposed 40 MHz oscillator at XI. Exercise the supported USB 2.0 and SuperSpeed modes separately. A cable or host that establishes only USB 2.0 can find the device without testing SuperSpeed. Verify the intended link mode, the associated bus, and sustained traffic. Then enter and exit supported low-power states and check when CLKOUT appears. Align the host's negotiated mode, controller status, and hardware capture.
As a control, use an intentionally USB 2.0-only connection on the same test board. Confirm that enumeration continues while SuperSpeed evidence disappears, then restore the supported high-speed path. This tests whether the fixture accidentally treats any enumeration as acceptance. If low-power recovery matters, log the control state, allowed delay, and first valid transaction. TI marks the TUSB1310A as not recommended for new designs. The procedure here concerns repair of installed boards. Qualify a 40 MHz active oscillator against the actual reference input, then qualify each downstream timing path in its own operating state.
On boards with several surface-mount oscillators, label physical test points by their function and pin number before removing anything. Preserve old and new waveforms in identical conditions. Even correct readings at all four frequencies should be followed by first-transaction and sustained-transfer checks.
Record the timing resolution of the fixture. A capture configured to inspect 25 ns reference periods may not resolve a short pulse on a 4 ns interface clock. When triggering from a power-state change, retain a long view of startup and a separate close view of the real clock edges. The former locates a problem in startup or recovery, and the latter checks the timing seen by the receiver. Also establish that probe leads have not altered the interface loading. Label whether the trace was measured at the driver or the controller.