A shared clock line stays low when its 48 MHz active oscillator is disabled. The fixture must establish whether that oscillator will load the next driver taking over. A zero reading can come from the receiving board, a weak internal pull-down, or an actively driven low. Isolate other drivers, hold the correct power and control conditions, and compare two known weak output biases.
Check output impedance after edges disappear
The SiTime SiT8008B specification distinguishes high impedance when OE is disabled from a weak pull-down in standby. Other series can differ. A low idle voltage alone does not identify the mode. Define acceptance with exact ordering code, supply, disable condition, and either static output current or a reproducible loading requirement.
Use a switchable weak bias on an isolated fixture. Verify that other push-pull drivers are off the tested node or in a qualified high-impedance state. Confirm normal clock output and enable levels first, then disable. Keep applied voltage and current within documented limits and verify that forcing a voltage during disable is permitted. The fixture should never drive against another active output.
Derive current from two bias levels
Suppose a 100-kilohm resistor connects 2.50 V to the disabled pin. A settled 2.45 V at the pin corresponds to 0.50 microampere. Another unit reads 0.20 V under the same conditions, about 23 microamperes. These are illustrative measurements. The second looks like an 8.7-kilohm load at that operating point, but the circuit need not contain such a resistor.
Apply another allowed bias, allow settling, and record current direction. Tracking both voltages with low measured current supports high impedance after fixture correction. Increased current only at higher voltage can indicate another conduction path. Reading both directions can expose incomplete settling or fixture switches. Strong drive and a weak pull both hold a line to one state without an applied bias. Their loaded behavior can differ.
Check the bench before the part
Take an empty-fixture reading with the same cable, socket, and meter, then verify a known load near the target. A ten-megohm meter at 2.45 V draws about 0.245 microampere, nearly half the example's 0.50 microampere. Measure or account for this burden, or use a suitable sensing arrangement. Total current through the bias resistor can include instrument and fixture paths.
Wait for charge to settle before reading static current. Twenty picofarads and 100 kilohms give about two microseconds as a first-order estimate. Real wiring can add capacitance and the device also needs time to disable. Use a waveform to verify timing. If disable speed matters, measure the last active edge separately against its own criteria.
Repeat at the real shared interface
For a replacement 48 MHz active oscillator, qualify static loading independently, then repeat handover on the shared line. Record when the first driver releases, when the next takes over, and how loading changes. A weak pull-down can affect the shared bus even when normal oscillation passes. If handover includes power-off, qualify its allowed pin conditions separately. Powered disable does not establish behavior with the supply absent.
Keep disabled state, both bias values, applied current, settling time, and fixture baseline. If output still settles low after changing parts, the evidence can distinguish expected release from a remaining pull path. A screen with no clock edges cannot make that distinction.
If a buffer isolates the shared line, test the oscillator terminal and buffer output separately. TI's SN74LVC1G125 specifies leakage for powered three-state operation and separately for zero supply. A released buffer output does not establish the oscillator's state upstream. Where relevant, test powered disable and specified power-off conditions and label the stage measured.
Check fixture-switch leakage and voltage drop. A current-limited source measure unit can record current direction at allowed voltages, or a verified high-impedance meter and resistor can retain the same calculation. Both require an empty fixture, a known load, and valid signal before and after disable. If a current range change produces a step, capture instrument state and repeat before attributing it to conduction.
Define fixture exit as well. Remove the test bias before restoring output under the product procedure. This keeps weak-bias measurement and full-speed verification under their own specified conditions.
Retain actual supply voltage at the part for each reading.