Two RF test channels share a 50 MHz active oscillator. Each reports lock and their frequency readings agree, but a fresh initialization does not yield the same phase relationship every time. Separate frequency, PLL lock and repeatable synchronization. Depending on the LMX2615-SP configuration, its SYNC pin must meet timing relative to the reference edge. Sharing a frequency source does not establish that both devices acted on the same reference edge.
Identify the synchronization category
TI divides synchronization into different cases according to the frequency and divider configuration. Use the manufacturer's decision diagram with the real reference, programmed output rates and path settings. The same nominal output can result from different divider paths. Read back both modules, confirm which modes the firmware selected and verify that each clock output uses the intended synchronization configuration.
For Category 3, SYNC timing against OSCin is critical. TI's table lists a 50 MHz reference condition and minimum setup and hold times of 2.5 ns. Setup is the time SYNC is valid before the sampling edge. Hold is the time it remains valid afterward. A GPIO transition distributed asynchronously to two modules can reach different parts of the reference cycle at each input. Compare SYNC with the reference at each synthesizer rather than only at the trigger distributor.
Calculate the margins within a 20 ns cycle
At 50 MHz a reference cycle is 20 ns. Suppose SYNC reaches one synthesizer 1.8 ns before the intended sampling edge and stays asserted well past it. Under the stated conditions, setup falls short by 0.7 ns. The other module might pass because the same trigger reached it earlier. Pulse width alone cannot show this difference.
Suppose instead SYNC is valid 7 ns ahead of the reference edge and remains so for 6 ns afterward. The illustrative setup margin is 4.5 ns and the hold margin is 3.5 ns before accounting for instrumentation, jitter, distribution and temperature. These example edges show how to calculate the two margins. Verify the actual device requirements for polarity, pulse width, initialization and common sampling edge before choosing a production timing value.
Measure at the receiver and repeat the restart
Compare SYNC and OSCin at the synthesizer using suitably fast instrumentation. Check for skew in the measurement channels with an available common source. For a differential input, use the crossing defined by the design and record the measurement points. Different clock output types and intermediate buffers can alter the distribution delays. When evaluating a 50 MHz oscillator, include the output levels and load as well as the nominal frequency.
Then repeat power cycling and phase synchronization with the same reference and interconnect, preserving the trigger and both output traces. A phase angle at a fixed frequency represents delay modulo a cycle. If the system needs a deterministic startup cycle, also capture output timing relative to the intended reference event. A stable displayed phase by itself cannot rule out an integer-cycle difference.
One useful control is to swap only the two synchronization distribution cables while keeping the reference, instrument trigger, power and device settings fixed. If the restart variation follows a cable, check distribution delay and arrival time. If it stays with one board, compare its pin waveform, input buffer, startup registers and supply sequence. Changing the reference and trigger path at once obscures which change moved the sampling edge.
Put reference and synchronization on separate acceptance rows
For the 50 MHz reference, identify the output type, stability, jitter test conditions and load after distribution. If a 50 MHz passive crystal replaces the active oscillator in a different design, verify its oscillator circuit, startup and resulting waveform against the OSCin requirements. For synchronization, record each SYNC source, setup and hold margins at the actual receiving pin, the configured synchronization category and repeatability after restart.
If frequency fails, check the reference and synthesis settings first. If frequency and lock pass but phase after restart does not repeat, investigate the synchronization category, the trigger edge and how phase was measured. These observations help purchasing quote the right clock and give the supplier an actionable record.
When sharing traces, include the reference period, probe location and timing definition for the trigger edge. Record the number of attempts and failures for a fixed configuration. Retain the same trigger positioning when comparing cold and warm results.