A 50 MHz oscillator keeps running. Why does the powered-down receiver rail rise?

A continuously powered controller sends its 50 MHz LVCMOS clock to a removable acquisition module. The module enters deep sleep and firmware turns off its 3.3 V rail. A scope still measures voltage on that rail, and the system draws more standby current than expected. Check the clock input's power-off specifications. An input clamp on some receivers can conduct current from the driven pin into the disabled rail. Compatible logic levels during operation establish a different condition from safe behavior when the receiver is off.

Find the current path

Measure the always-on and switchable rails independently. After turning off the module, record whether its rail initially falls and later rises while the oscillator continues. Use the design's clock enable or isolation to remove that signal temporarily. Observe whether the current and voltage change together. If voltage remains, check data, reset, and debug wiring. A high-impedance meter can indicate a voltage from very small leakage, so a reading alone does not establish substantial current. Measure the applicable supply current and interpret it with the receiver's power-off specifications and board load.

An illustrative clamp calculation explains why a small series resistor may be insufficient. Assume a 1.8 V source and a receiving input clamped near 0.4 V just after power-off. With 100 Ω series resistance, ignoring driver resistance and parasitics, the instantaneous 1.4 V difference corresponds to 14 mA. Real current depends on the output impedance, clamp characteristic and the rail voltage as it rises. This is neither a device limit nor a basis for estimating standby current by halving 14 mA. Raising resistance changes threshold timing. A 50 MHz half-cycle is only 10 ns, so check the driver, cable and capacitive input together. A current-limiting scheme must satisfy the receiver's specified powered-off injection conditions.

Qualify isolation and normal operation separately

TI's SN74AXC1T45 is one example of a dual-supply single-line translator. Power A from the permanent 1.8 V domain and B from the switchable 3.3 V domain, and select A-to-B direction as documented. The data sheet specifies Ioff for partial power-down and high impedance on both data ports when either supply is below 100 mV. The intervening region during a slow power ramp needs separate consideration. A complete power-off check does not establish a valid clock or guaranteed high impedance throughout an out-of-range supply transition. Hold the receiver in reset until power and clock both qualify, or define which input states the system accepts while ramping.

During normal operation, TI describes support up to 500 Mbps in the specified 1.8 V to 3.3 V direction. A 50 MHz clock alternates every 10 ns, corresponding to 100 Mb/s of alternating bits. Being below the stated signaling rate does not demonstrate pulse width, setup, or hold at the receiver. Check both propagation edges for the selected rails, direction and load. For assumed delays of 3.4 ns rising and 4.1 ns falling, a 10 ns input high becomes about 10.7 ns at the output and the low becomes 9.3 ns. A board requiring both to be at least 9.5 ns fails that example even though a counter still reads 50 MHz.

Exercise real power transitions

Test both rails on, repeated receiver power cycles, and the slowest ramp with the shortest permitted off interval. Capture source clock, actual receiver waveform, switched power and receiver reset. Preserve maximum rail rise or leakage during power-off, time to first usable clock, and first successful application transaction. A short off interval may leave residual rail voltage. Record where pull resistors get power so current from another rail does not get attributed to the clock.

Provide oscillator supply and output code, receiver operating and powered-off limits, and translator supply ownership in the qualification record. If the module may lose its clock during power-off, demonstrate both isolation current and resumed pulse width. If a timekeeping domain must stay alive, define which domain retains a clock. Those are reproducible test conditions for a clock sample.

Compare fast and slow shutdown ramps to distinguish capacitive transients from continuing backfeed. Document the observation window and the final rail voltage before and after gating the clock.

If a pull-up defines the state during power-off, record its rail. A pull-up to the always-on domain can still conduct through the unpowered receiver even when the translator is high impedance. Test with only the clock signal connected, then restore other signals independently. Start each test from settled supplies and compare the same observation window. Residual charge from the preceding run can otherwise make the answer depend on test order.

Use both an extended off interval and the shortest one the equipment permits. The long interval shows where the isolated rail settles. The short one exercises whether reset remains asserted while residual voltage is present. If firmware knows only that a power command was sent, validate the actual power-good or other readiness indication. Keep the production oscillator and enable sequence in the test. A fixture that stops the clock before cutting power could miss the path being investigated.