A scope measures a 50 MHz spread-spectrum oscillator against an ideal fixed clock. A large timing-error curve repeats every few tens of microseconds. Turning on spread-spectrum removal leaves a residual of tens of picoseconds. The measurements use different references. One preserves the clock motion the receiver must track. The other compares jitter outside the intended modulation. Keep both results and check the instrument's treatment of each component.
Identify the modulation and timing reference
Epson lists spread direction, width, modulation rate and profile as separate SG-9101 settings. Verify the sample's configuration and check actual modulation rate and direction on a continuous waveform. If a scope or phase-noise option removes SSC, determine whether it uses entered parameters, automatic estimates or a particular recovery mode. Keysight documents an SSC removal setting. Identify which acceptance result used it.
Capture qualified edges at the receiver using the same threshold, bandwidth and connection for both measurements. The fixed reference may use a specified nominal frequency or a consistently determined average frequency. With down spread, these references can produce different long-term slopes. Document the selected reference and whether average offset is removed. Otherwise a different time reference alone can affect comparisons between samples.
Include several complete modulation cycles in a continuous recording. Acquire source and receiver together where possible. Flag gaps from segmented acquisition or loss of lock. If timing error exceeds one cycle, a modulo-period display loses the excursion. Use unwrapped phase or track edge numbers against expected times and verify that no trigger reset interrupts the timing relationship.
Estimate how much timing motion the modulation produces
Suppose a 50 MHz clock uses sinusoidal center spreading with a peak frequency deviation of 0.50%, or 250 kHz, at a modulation frequency of 25 kHz. For small fractional deviations, timing error relative to a fixed frequency is approximately the integral of fractional frequency deviation. The peak amplitude is 0.005 divided by two pi times 25,000, or about 31.8 ns. The peak-to-peak excursion is about 63.7 ns. Since the clock period is 20 ns, this spans more than three cycles. The example does not specify a commercial part's guaranteed result.
For triangular or other profiles, integrate the corresponding waveform. Identical frequency endpoints can produce different timing-error traces. If the system uses clock recovery to track the spread, verify that the input range and rate fit that loop. Removing the modulation in analysis does not remove it from the signal applied to a receiver.
Preserve faults during residual jitter analysis
When removing SSC by instrument configuration, retain paired results from the same record and include recovery and analysis bandwidth. For offline analysis, use the known shape and measured modulation cycle to form a template. Align it to the modulation reference and test it against held-out full cycles. Fitting an arbitrary curve to every cycle can absorb real periodic disturbances. Check alignment at the extrema and transitions.
Suppose the project's residual limit is 50 ps RMS and a matching record gives 41 ps RMS. That item passes. Also inspect time records and the residual spectrum for spikes at supply-related frequencies or repeated at the same modulation phase. A fault that always occurs at the slowest point can appear coherent with normal spreading. Compare the source template with the simultaneous receiver waveform, or use a verified non-spreading reference sample where permitted. Keep receiver-specific filter settings with the measurement.
Check both results against operating hardware
Compare the original and candidate 50 MHz spread-spectrum oscillators at identical load, supply and temperature. Record raw timing excursion, residual jitter, receiver lock and recovery. If residual jitter improves while the receiver still loses lock, investigate frequency range, modulation rate and other timing limits. A single low jitter number needs its modulation configuration, observation duration and analysis setting before purchasing can compare it with the requirement.
Keep raw records and settings for a check with a known disturbance. If the bench can add a calibrated small phase modulation, verify that the SSC correction does not suppress that new in-band component unintentionally. Repeat this check after a change of instrument or software to separate measurement-processing changes from oscillator performance.
When comparing suppliers, fix integration bounds and whether discrete spurs are included. A report that removes every narrow spur cannot be ranked directly against one that removes only the SSC template. For a borderline result, retain spectra and timing-error trends before and after removal, and identify components associated with the specified modulation. Keep the unfiltered record for comparison with hardware lock events.