The host starts a read when DOUT falls. Some identical sampling commands produce the notification and some time out. A 50 MHz active oscillator provides the timing reference, and CONVST spacing checks out. In the ADS8860 four-wire CS mode with a busy indicator, DIN during conversion determines whether the indication is produced. Compare the actual DIN edge with the conversion-time limits before attributing the behavior to the clock source.
DOUT carries both the indicator and the data
TI's data sheet states that DIN is high at the rising edge of CONVST to select CS mode and initiate acquisition of the sample. The ADC uses its internal clock for conversion. For the low completion indication on DOUT, pull DIN low before the minimum conversion time and keep it low through the maximum. An external pull-up holds DOUT high while the line is in its high-impedance state. Measure DIN at the ADC itself. The host's chip-select register cannot establish the edge after any external buffering.
For the four-wire example with AVDD and DVDD each at 3 V, the data sheet gives a conversion time from 500 to 710 ns. The host is timed by a 50 MHz active oscillator, or 20 ns per tick. DIN falling at tick 20 is about 400 ns after CONVST, 100 ns ahead of the minimum. At tick 26, it falls around 520 ns, 20 ns after the minimum. Actual conversion times can differ by part and condition, so the later plan can fail intermittently.
Move the falling edge and capture both responses
Begin with a sampling period that leaves room for chip select, serial read, and ADC acquisition. Apply a stable input with a predictable output code and observe CONVST, DIN, DOUT, and SCLK. Use the specified pull-up and check that DOUT measures high in the idle high-impedance interval. Capture the 400 ns and 520 ns cases. Measure at the ADC pin relative to the same CONVST threshold. Keep the probes and acquisition filtering fixed.
If DOUT falls immediately after DIN, especially when both edges shift with a late selection, check whether the event is the indicator or a low most significant data bit. Apply two analog inputs whose expected MSBs differ and verify them by a known low-speed read. The actual busy indicator is a low bit independent of the MSB. On the path without a requested indicator, asserting DIN can reveal the MSB directly. The input-code comparison separates those cases.
Verify the serial sequence after the notification as well. In four-wire mode with the indicator, DOUT presents one indicator bit followed by 16 data bits, requiring 17 falling edges per the timing diagram. Without the indicator, the four-wire sequence uses 16. Mixing the parsers can shift every sample by a bit. Save the raw serial order at a stable analog input to verify that software removes the indicator rather than judging only its final decimal display.
Remove the timing boundary before comparing components
Move DIN earlier and hold it through the documented window. Repeat under the heaviest combination of interrupts or a shared SPI bus. If the 50 MHz oscillator stays steady and missing indications follow late DIN, investigate host scheduling, buffering, and the chip-select path. Retain a known passing and failing trace for the production station. Record missing notifications and serial read errors separately, with the number of actual conversion commands. If the timing margin is adequate but DOUT fails to return high, inspect pull-up, bus loading, and added probe capacitance.
A separate control uses the documented four-wire sequence without the busy indicator. Return DIN high before the minimum conversion time, then wait past the maximum before asserting it for the read. Use the corresponding word length and clock edges. When that yields repeatable samples while the indicator mode fails only at short select margin, the captures establish that the ADC still converts. An interrupt handler expecting a busy indication cannot be reused unchanged for this sequence.
As a separate control with early assertion, move the end of the DIN low interval into the conversion window. If only earlier conversions still signal, both ends of the selection window need testing. Observe the pull-up recovery with a low-capacitance probe. A long test lead can add delay to the notification crossing.
On a shared bus, disable the other selections for a control capture with the original input network, then restore the heaviest expected load. If the indicator looks right at the ADC but never crosses the interrupt threshold at the host, inspect the level and loading there before the read. Extending the select timing alone leaves a host-side detection fault in place.
Record CONVST cadence, the measured DIN times at the package, indicator and data bit counts, voltage, and temperature. Test a candidate 50 MHz active oscillator with the same firmware and ADC. If changing the specimen alters the reported ordering, use a common capture to decide whether the source is unstable, the actual frequency crosses a tight boundary, or the chip-select schedule already has inadequate margin.