A 50 MHz active oscillator runs continuously on a digital board. The CDCLVC1104 supplies its clock to a peripheral only when requested. A frequency measurement looks correct after every restart, but the peripheral occasionally misses a count or advances unexpectedly. Capture the first and last pulses around enable changes. Steady-state frequency and the behavior of an enable transition during an input high phase are separate checks. A counter averaging thousands of later cycles misses both boundary pulses.
Asynchronous enable does not wait for the next full clock pulse
TI describes this buffer's enable as asynchronous. When it is low, the outputs are driven low. With enable high, the outputs follow their input. If the input is already high when enable takes effect, the output can rise partway through that high interval and fall with its end. Disabling an active high output can truncate the last pulse. A synchronous-enable buffer's behavior does not apply to this device.
A nominal 50 MHz active oscillator has a 20 ns period, with a 10 ns high phase at 50 percent duty cycle. Suppose eight nanoseconds of that phase have elapsed when an ideal gate opens. Only 2 ns remain. Real control and clock paths have different delays, so this describes phase overlap, not a predicted output pulse width. If the peripheral requires at least 4 ns high and a 2 ns pulse is observed at its pins, the boundary pulse fails even when the steady-state frequency passes.
TI lists input-to-output propagation separately from enable and disable timing and shows the measurement thresholds. Use consistent scope thresholds to compare captures, then check the actual receiver thresholds and load. A short pulse that never reaches its usual amplitude may be counted by one receiver and missed by another. An analyzer can hide it completely. Use sufficient scope bandwidth with the intended receiver load in place.
Capture both opening and closing
Hold the oscillator on and vary the enable phase reproducibly. Test several positions inside the high and low intervals. Capture input clock, enable, buffer output and actual peripheral input. Record the shortest first and last high widths and when the output becomes low. Include the longest route and heaviest relevant load. A good first pulse on a short trace does not cover every output.
Save the peripheral count or state alongside the traces. Extra counts while the output stays low suggest another path or a register-read timing issue. A count error recurring only when enable overlaps an input high phase suggests keeping the receiver in reset until complete clocks are present, or changing enable timing under a verified clock constraint. Check maximum control-path delay against the minimum actual low interval for any such design. A software instruction scheduled after a falling edge does not establish timing at the buffer pin.
Test the last pulse too. A peripheral that commits state immediately before its clock stops can be affected by a shortened final high phase. Stop after a known number of cycles and verify the committed state. When the rest of the system also removes power or resets, first test clock gating with receiver power intact, then repeat the normal sequence. This separates boundary pulse behavior from power loss and incomplete peripheral recovery.
Do not reuse control timing unchanged across supply variants. The switching table lists up to 6 ns from enable or disable to output at the 3.3 V condition and up to 10 ns for the 2.5 V condition under the stated measurement setup. A 20 ns clock at 50 percent duty cycle has only 10 ns low. The slower maximum is already comparable to that nominal interval. A change scheduled from the input's falling edge must still account for controller delay, clock-path skew and duty-cycle variation. A measured low phase below 10 ns does not support a claim that this strategy covers worst case. Use the actual receiver's levels and load in the system timing check.
Specify both steady-state and transition checks for the sample
Qualify the 50 MHz active oscillator against levels, duty cycle and supply conditions. The asynchronous buffer also requires deciding whether the receiver may ignore clocks around start and stop. If complete first and last pulses are required, validate the control or buffer arrangement against that condition. Retain the steady waveform, worst enable-phase captures, actual load and measured peripheral response. The measured clock at the receiving pin determines whether it can safely start and stop.
