A fixture uses a DAC8760 to simulate an industrial current transmitter. The host is referenced to a 50 MHz active oscillator. An ordinary sweep covers 4 mA to 20 mA. After an external clear, the pin returns low but the load still measures the bottom of the range. The host log contains the old target and the serial bus still moves. Capture CLR, LATCH and current at the device. Releasing CLR permits later operations. It does not restore the former output by itself.
Separate clear from the power-up default
TI specifies an active-high asynchronous CLR. An enabled current output goes to the low end of its programmed range. In 4–20 mA mode, expect about 4 mA. The bottom of a 0–20 mA range is zero. Immediately after power-on reset, the current output defaults to high impedance, which is another case. Identify range and output enable before treating a low reading as evidence of clear.
The voltage output has its own clear selection through a pin and configuration bit. Dual-output operation also has data-register implications. First reproduce the behavior with current output alone on a load fixture. Verify the other output configurations separately if the product uses them. Measure steady current and capture the transition. If programmable slew is enabled, confirm the time required to reach the cleared value under that setting.
Compare two known readings across a fixed load
With a suitable 250-ohm precision load, command 12 mA in the 4–20 mA range. Ohm's law gives about 3 V normally and about 1 V at 4 mA after CLR takes effect. This distinguishes a controlled clear from lost output power. Budget load tolerance, current error and instrument error. Supply compliance, cable and protection drops can all affect the real loop.
Assume the 50 MHz active oscillator references a measured divide-by-eight SPI clock of 6.25 MHz. A plain 24-bit transfer without CRC takes a nominal 3.84 µs at that rate, excluding latch, software and output movement. Use it to locate the serial operation. Do not compare it directly with how long the load takes to reach 1 V. TI says a new value cannot be programmed while CLR remains high. Check the latch and clear together even if clocks appear in the trace.
Verify whether the product restores its old value or accepts a new one
The output stays at the cleared value after CLR goes low. On a controlled current-only bench, first exercise the documented recovery of the pre-clear value with a LATCH pulse and no new clocks. In a separate test, send and latch a distinct new value according to the product sequence. Distinct commands make the two outcomes visible. Use an isolated fixture if the real product waits for permission before changing a connected actuator or load.
Another circuit may assert CLR briefly and release it before software reads a GPIO. Trigger on the active edge and capture supply, latch and output on the same timeline. Compare with an ordinary code change while CLR remains inactive. Save the value the software intended to send and the value measured at the load. They can diverge during clear.
Keep a dynamic capture with the same range and load. Mark clear assertion, release, restore command and settled output. Define the origin of recovery time at the device pin, rather than assuming a software log marks the same instant. If slew limiting is enabled, confirm the configuration after firmware changes before comparing settling behavior.
If a cable, load or board change introduces the symptom, compare steady operation on a known fixture load with the same range and command. Where compliance allows, command a brief increase and check whether current follows. A persistent lower limit accompanied by valid CLR pulses points toward the clear path. If load voltage reaches the available supply limit while current is low, investigate loop compliance. Record load voltage and loop current together so similar low readings do not get assigned to the same logic cause.
Record the 50 MHz active oscillator specification and measured serial clock separately from the current-loop test. Verify the cleared value and the required recovery action with the chosen load. The board passes recovery when its current responds correctly to the next intended command.