An industrial i.MX RT106x board shares a 50 MHz active crystal oscillator between its MAC and Fast Ethernet PHY. Traffic passes in the normal operating mode. With a lower-power configuration, the port still reports link while frame reception becomes intermittent. Both RMII pins continue to show a 20-nanosecond reference period. The pin-level reference and the processor's peripheral clock have separate requirements.
Configure the MAC direction and clock source
NXP AN14251 Section 4.3.3.2 shows either the MCU or an external source supplying RMII. With an external 50 MHz active crystal oscillator, select the proper clock pin and its input configuration. Clear the selected instance's TX_CLK_DIR in IOMUXC_GPR_GPR1 to disable its output driver. Set its CLK_SEL to one to use the external reference. ENET and ENET2 have separate fields. A change in the device driver does not establish that the input multiplexer is correct. If an older build drove the reference from its own PLL, check when that driver is disabled to prevent a startup interval with two active outputs.
Read back the actual board configuration. Verify the pad identity against the routed net. A PHY may see the correct external clock while the MAC selects another source. Observe the pin before and after MAC reset release, then verify pin multiplexing and clock selection. Preserve both the physical clock trace and the configuration showing where the MAC actually takes its clock.
Recalculate the IPG root
The same application note requires an ipg_clock_root of at least 50 MHz in RT106x RMII mode, including with an external reference. Suppose the internal parent runs at 132 MHz. Divide by two to obtain 66 MHz. Divide by three and the result is only 44 MHz, six megahertz below the minimum. The 50 MHz active crystal oscillator remains unchanged at the connector. Occasional successful traffic does not make the 44 MHz configuration compliant.
Record the parent selection, division ratio, and module gating, rather than only CPU speed. Translate raw register values using the clock controller's divider encoding. Keep the PHY and external reference unchanged while comparing the internal clock settings and traffic. If the root is below the minimum, rerun the traffic check with a compliant configuration before changing board components.
Test the interface in its operating modes
The RT1060 industrial data sheet specifies a continuous 50 MHz RMII reference with ±50 ppm tolerance. That corresponds to 49,997,500 through 50,002,500 Hz. Allow for temperature, aging, and measurement when evaluating the source. Frequency alone does not qualify swing, duty cycle, or signal edges. Check the clock at both loads. If the reference stops during a low-power mode, verify whether network operation is intended during that interval.
Save normal traffic, reference waveforms around the mode transition, the IPG settings, and the first frames after recovery. A PHY ID and a link light cover only part of the interface. Exercise actual transmit and receive paths. When using the same 50 MHz active crystal oscillator for comparison, log the external reference and the processor's internal peripheral clock separately.
Some power policies restore the bus rate only after a particular task resumes. Mark the change on an output and save the clock configuration near that marker, then mark receive recovery. A later console print is not the hardware receive time. If software buffers frames, record sequence numbers so a brief delivery delay can be distinguished from missing frames using a repeatable local traffic source.
Give the physical reference and the processor clock separate fixture checks. Measure the waveform and continuity at the MAC and PHY. Load the shipping firmware and verify IPG settings in normal and low-power states. A bootloader or recovery image may configure the pin differently. A correct final direction does not show whether it drove the pad during boot. Observe the ordering when devices have independently controlled power.
If clock edges are missing, localize the branch with the interface held in the same operating state. When the source is continuous and only one load shows abnormal levels, inspect its loading and pad configuration. If both input waveforms remain healthy and frame reception fails only in one operating mode, review IPG and clock gates before trying a different oscillator.
When a board uses both Ethernet instances, retain the direction, clock selection, and traffic results per port. The two PHYs may share the management bus. Reading one PHY does not establish that the other clock input is configured. Exercise each port individually and then together to check for conflicting software configuration.
