The board routes a 50 MHz oscillator across two voltage domains. A counter reports 50 MHz on both sides, but the receiver sometimes fails at low temperature. Measure rising and falling propagation delays separately. Equal delays shift the waveform as a whole. Unequal delays redistribute high and low times even when frequency is unchanged.
Identify where each part of the waveform is measured
Mark the oscillator output, translator input, translator output and actual receiver input. Even on a short trace, distinguish the translator output from the loaded receiving pin. Record both supply voltages, loading and the datasheet conditions for propagation delay. TI's TXU0101 is a fixed-direction dual-supply example whose delays are specified with defined supply and load combinations. A product page's maximum data rate does not guarantee the required minimum clock widths at every voltage combination.
Capture input and translated waveforms simultaneously. Deskew both channels with a common check edge and use ranges appropriate to each rail. A 1.8 V input and 3.3 V output have different threshold voltages. Use the datasheet's measurement convention when comparing propagation delays. For acceptance, verify pulse widths against the real receiver's thresholds and waveform at its pin.
A probe can add enough capacitance to slow one transition. Verify the setup on an engineering sample with known loading and use low-loading probes where possible. Probe or comparator paths can also have different delays for rising and falling edges. Retain calibration results and observe the translator rails separately. Synchronous signal capture alone does not establish stable supplies.
Calculate how much time moves out of the high state
Suppose the input is high for 9.5 ns and low for 10.5 ns. Its period is 20 ns. Under defined thresholds, rising propagation delay is 5.8 ns and falling delay is 3.2 ns. Output high time equals input high time plus falling delay minus rising delay, or 9.5 + 3.2 − 5.8 = 6.9 ns. If the same delays recur next cycle, output low time is 13.1 ns. A counter still reports 50 MHz correctly.
If the receiver requires at least 7.5 ns of qualified high time and the measured interval at its threshold is 6.9 ns, the margin is short by 0.6 ns. If 6.9 ns came from the translator's percentage thresholds, measure at the actual receiver again. Slow edges can widen the difference between these definitions. Use propagation delay for diagnosis and measured receiver widths for acceptance.
Two maximum propagation delays in a datasheet need not occur together on one device. Use a specified maximum edge-delay difference or pulse-width distortion where available. With independent delay limits, preserve those ranges instead of simply subtracting their maxima. Include worst-case input duty cycle, wiring and thresholds. Verify cold, load and supply corners because a single room-temperature record cannot represent every condition.
Check the missing time against actual receiver operation
Set a trigger for pulses narrower than the receiver permits and record input and output together. If input width already violates the oscillator specification, check source load or settings. If it is correct and only the translated pulse shrinks, compare an approved alternative translator, termination or lower-loading probe on the engineering board. If the translator output passes while the receiving pin fails, inspect the interconnect and input thresholds.
Separate continuous operation from enable and startup. A dual-supply translator can enter a high-impedance state when a supply is missing or output is disabled. Follow the datasheet and board sequence for the first pulse. A narrow pulse only near enable cannot be explained just by steady-state propagation delays. Check whether the receiving system begins sampling before the translated clock is valid.
For a replacement 50 MHz oscillator or translator, keep original and candidate records of thresholds, supplies, load, temperature and matched pulse widths. The receiver must meet its minimum high and low times and usable timing margin. If a few hundred picoseconds only appear under one threshold definition, verify the setup before attributing the difference to component or placement.
Where an engineering mode permits, drive the translator with a verified source at fixed frequency and vary duty cycle in known steps. If widening the input by one nanosecond similarly widens the output, a fixed delay difference is plausible. Abrupt collapse below a narrow width suggests a minimum input-pulse or voltage limit that should be checked against operating conditions.
During chamber reproduction, save rails and output widths together with unchanged probe settings. If widths fail only at the beginning of cooling, let the device stabilize and repeat to distinguish a thermal transient from a steady operating boundary. Use the verified narrow pulse to reproduce the receiver failure.