A 50 MHz active oscillator keeps running while a downstream switch passes bursts of clock to a receiver. On a spectrum analyzer the gated carrier is lower than the continuous carrier, with a comb of nearby lines. It is easy to call this insufficient oscillator output or to count every comb line as clock jitter. Compare the continuous source with the useful portion of the gated output and document the time window.
Account for the carrier line and comb using time measurements
Pass the oscillator's fundamental through an appropriate interface to an external switch. Suppose the gate opens for twenty-five microseconds every 125 microseconds. The pulse repetition frequency is eight kilohertz and duty factor is twenty percent. Each open window contains approximately 1,250 carrier cycles. For a continuous phase-coherent carrier, an ideal rectangular gate produces lines eight kilohertz apart. The first envelope null is about forty kilohertz from the carrier, the reciprocal of pulse width. Finite switching edges, leakage, and changing amplitude alter the details. The calculation predicts the main spacing.
At unchanged in-pulse level, carrier-line amplitude scales with duty factor. With a twenty-percent rectangular gate the line power is about 13.98 decibels below continuous wave, because the power ratio is the duty factor squared. Total time-averaged power integrated across all lines is approximately 6.99 decibels lower, following duty factor directly. A fixture that labels center-line power as actual in-pulse power is off by nearly fourteen decibels. Keep analyzer bandwidth, the continuous reference level, and the independently measured in-pulse level.
Measure the clock and gate in time, then compare the spectral spacing with the gate repetition rate. If repetition rate changes at constant width, the comb spacing changes while the nominal first null does not. If width changes at constant repetition rate, the envelope width changes. These tests identify lines due to periodic gating. For narrow lines that do not track the repetition rate, investigate supplies, external synchronization, and phase fluctuations.
Avoid the pulse edges while keeping a long record for close-in noise
Rohde & Schwarz describes using a time gate to select data inside each pulse. Its automatic example centers a window of about seventy-five percent of the pulse width. Manual operation can specify delay and length. On a twenty-five-microsecond pulse, a seventy-five-percent window is 18.75 microseconds and occupies fifteen percent of the full period. It excludes about 3.125 microseconds on each side. Check amplitude and phase settling before using that exclusion. The instrument default alone does not establish a stable region.
A single twenty-five-microsecond pulse cannot support a complete close-in phase-noise result. A suitable method needs records spanning many repetition intervals and a defined offset range. The manufacturer shows a maximum offset at about half the repetition frequency for its example technique. For eight kilohertz, use four kilohertz as an initial upper bound for this method and check instrument mode and aliasing. Do not extrapolate to a requested ten-kilohertz offset. Continuous wave establishes the source baseline; gated-mode results belong to their specified conditions.
Shift the analysis window for a comparison. Measure in the settled middle and then nearer the opening edge with a similar window length. Compare phase noise or phase residuals. Behavior that worsens solely in the early window suggests switch or drive settling. If both settled windows show additional noise, check the source, load, and the instrument floor under pulsed operation. If the receiver uses the first few cycles, measure those separately. Excluding startup edges from a noise estimate does not prove their timing meets requirements.
To gauge background introduced by gating, apply a continuous source characterized at the offsets of interest. Use the same switch and gate sequence. Match in-pulse powers so the analyzer operates at comparable gain. If both sources show a similar raised floor after gating, investigate limitations associated with repetition and measurement first. If only one shows extra narrow lines, check modulation or supply noise. Save the ungated comparison source trace. Its own phase noise and frequency error prevent treating the difference as an exact point-by-point correction.
Accept the actual clock conditions
If the design runs the 50 MHz oscillator continuously, establish the source baseline, gated-output phase noise, and receiver first-edge timing separately. If the oscillator itself restarts for each burst, phase may not be continuous. Reassess whether the same pulsed phase-noise technique applies and capture repeated startups for system acceptance. A same-frequency replacement may change in-pulse level, startup behavior, or the duration of the transition. Verify the selected window again.
Record pulse width, repetition rate, gate placement, reference power definition, offsets, and instrument mode. Obtain a continuous reference first, then measure the product with its switch in use. If a short gate leaves insufficient analyzer dynamic range, mark that offset as unverified rather than assigning a misleading value.