The persistence display looks clean after a board with a 50 MHz active oscillator runs on the bench for half an hour. The system log still shows an occasional wake-up failure. Find out how many wakes the test observed and which complete waveforms reached memory. Display time, recorded time, and trigger readiness describe different parts of the experiment. Half an hour of wall time cannot stand in for all three.
Start with recorded time and the receiver window
Suppose a simple edge-triggered setup saves five hundred records per second, two microseconds each, with no overlap. It retains one millisecond per second, or about 0.1 percent of elapsed time. At 50 MHz each period is twenty nanoseconds, so every record contains about a hundred cycles. The display can look full even when it omits many events. Tektronix distinguishes waveform capture rate from sample rate and notes that burst capture can be followed by substantial processing dead time. This calculation applies to the stated example. Actual fault-trigger coverage still needs verification.
If missing pulses occur after a wake, ordinary clock edge triggering can bias the sample toward steady operation. The edge of interest may be absent and cannot trigger a capture. Use an independent wake marker and start recording early enough to keep pretrigger data. Continue until receiver reset releases or the first clock-dependent action occurs. A missing edge can then be detected within a record that spans the relevant window.
Define valid amplitude, high and low width, and edge spacing at the receiver. A half-height pulse and a complete absence of edges may need separate detection conditions. Use the receiver threshold where applicable and keep valid output from before and after an anomaly. Tie coverage to those definitions. Reconfirm that changes to probe bandwidth, filtering, or threshold preserve detection of the specified problem.
Give the event an independent count
Save every requested wake marker and match it to the acquisition sequence number. In a controlled verification, program a test source to skip a pulse, or exercise an appropriate debug or simulation interface. Keep active oscillator outputs within ratings. Verify the reported position of the known anomaly and check whether a missing record or buffer overflow is also visible. If the known fault is missed, examine trigger readiness, record duration, rearming, and transfer gaps.
Segmented capture can retain more original waveforms for rare faults. It can still reject a new trigger during rearming. Allow enough time between stimuli at the actual instrument settings and reconcile event and capture counts. It may be possible to slow the stimulus or start the next trial only after a ready signal. This trades throughput for verified exposure.
Interpret zero failures in terms of valid trials
Suppose the audit discovers three thousand complete, comparable and independent wakes with zero predefined failures. In the simple binomial model the probability of all successes is one minus p, raised to the three-thousandth power, for single-trial failure probability p. Setting that probability to five percent gives a one-sided 95 percent upper limit of about one in a thousand. It applies to the stated conditions and failure definition. Rare failures remain compatible with that observation.
Repeated cycles on the same board share temperature, fixture, firmware, and component state. With short interruption intervals, residual voltage can depend on the previous trial. Log samples, temperature, power-off interval, and the acceptance definition. Group evidence by lot or board when conditions differ. Compare the two materials only after obtaining comparable effective exposure.
Record missed captures during substitutions
Test a replacement 50 MHz active oscillator under the original board and wake conditions. Report attempted, valid, failed, and missing captures. If a chamber position produces normal wake markers with fewer captured records, verify trigger readiness and allocation first. A failure following one device between receivers warrants a check of that device's startup waveform. If it occurs only with a particular power or reset setting, keep the conclusion specific to that condition.
One missing pulse may be tolerated or may cause a receiver reset. Match captured waveforms to system events to see whether the proposed cause reproduces the observed failure. For startup acceptance, fix the observation window around the time the clock is first used. Screening for missing pulses at any point during operation requires separate verified coverage of that interval.
If several bad edges appear in one window, count one failed wake and record the number of affected edges separately. Otherwise different failure patterns can be mistaken for different probabilities of a failed wake.