A 50 MHz oscillator stays on. Why is there voltage on the switched-off rail?

A board has a 50 MHz active oscillator on its always-on supply. A downstream logic domain powers up only as needed. After shutdown, the supposedly discharged supply settles at several hundred millivolts. Host logs declare it off, yet restart sometimes fails and sleep current is higher. Temporarily disconnecting the clock path can reveal whether the signal from the powered domain contributes to the residual voltage.

Make the powered-off condition repeatable

If a signal remains high enough to forward-bias a protection structure in a powered-down device, current can enter its supply. Texas Instruments distinguishes ordinary logic from circuitry with powered-off protection. The latter limits port leakage under defined data-sheet conditions. High impedance under normal power and electrical isolation with the supply actually at zero are separate tests. External pullups, other signals, and probe connections can also contribute. One supply reading cannot identify the injection path.

Identify the always-on and switched domains from the schematic, and find the supply test point close to the load. Capture the switched rail, actual clock input, and power-switch enable with one trigger. Begin each shutdown after the same on-time. Check how the fixture supply behaves when disabled. Some units actively discharge their output, while others sink almost no current. Both may show zero on the panel and leave different voltages on the board. Keep the grounding and measurement arrangements appropriate for the board.

First record shutdown with the 50 MHz active oscillator driving. Repeat with the same supply timing and just that clock disabled or isolated at an approved point. Use an existing removable series link or a control verified to enter high impedance. A static low comparison can also help if it causes no driver contention. Restore the clock and repeat. A plateau occurring only with the clock present implicates the path. If isolating it leaves the same voltage, check other signals from the always-on domain one at a time.

Convert the rail voltage to current with a known load

A small net current can raise an otherwise floating rail with bypass capacitors. Use a known bleed resistor on an engineering sample when permitted, or characterize the existing network. Suppose that a 100-kilohm resistor sees 0.42 volts with the clock connected and 0.06 volts with it isolated. The resistor currents are 4.2 and 0.6 microamps, a difference of 3.6 microamps. That is the change through this resistor only. Other branches can change current with rail voltage. This number is not a leakage specification for the oscillator.

The slope can provide a cross-check over a nearly constant-current segment. Four microamps of net charging into one microfarad raises voltage by about four volts per second, equivalent to 0.1 volts in twenty-five milliseconds. Net current here already excludes discharging current at that time. Actual capacitance varies with bias and the protection path can be nonlinear. Use the result as an order-of-magnitude check. Save any portion where the slope changes abruptly as a separate observation.

Where the part ratings permit, compare a static low input with the normal clock. A clean rail with the input low but a step during high portions points toward a protection path. A brief peak followed by full discharge is more consistent with capacitive coupling or ground bounce, although it could still cause a reset or interrupt. Log sustained residual voltage and transient amplitude separately.

Also check whether the reading changes when the probe is connected. Even a high-impedance probe adds parallel resistance to a floating node, and a meter and scope can differ by an order of magnitude in input resistance. Use a known stable load at the same test point before comparing instruments. If the residual voltage changes markedly with instrument range or termination, record instrument loading with the result. Check near the load and on both sides of the power switch to exclude a local voltage caused by an intermittent connection.

Verify a buffer at zero volts and through transitions

The SN74LVC1G125-Q1 data sheet, for example, specifies partial-power-down behavior at zero supply voltage and describes using a pullup on its active-low output enable. Place any replacement buffer in the intended power domain and test the entire power sequence. Ioff defines leakage under stated bias conditions. It cannot establish behavior at every voltage between zero and the normal rail. After a substitution, use the real 50 MHz active oscillator to verify receiver levels, timing, and restart. A slow bench demonstration does not establish performance at the operating clock rate.

Specify allowable residual voltage and extra standby current separately. Record when the measurements were taken, any added bleed load, clock enable state, and worst restart time. At a borderline result, isolate the device and board paths before changing the specification. If the new oscillator's high level or edge rate changes injection, repeat at the intended extreme temperatures and supply voltages. Close the issue when the rail discharges, the system restarts, and the running clock meets the receiver requirements.