The approved order is ABLS-11.0592MHZ-B2-T, but the quote says ABLS-11.0592MHZ-T. Both specify 11.0592 MHz and retain the tape suffix. Abracon's ordering diagram uses letters and numbers for operating temperature and initial frequency tolerance, with defined defaults for blanks. The shorter code cannot be treated as an abbreviation for the approved part.
Align the fields and check each default
The ABLS drawing uses B for −20 to +70 °C and 2 for ±20 ppm initial frequency tolerance. Verify the load and temperature range for the exact B2 option from its product documentation. Obtain the corresponding specification or approval sheet for the option without B2. Both parts may have the same load capacitance, so an unchanged capacitor network does not establish the same temperature range or frequency tolerance. Do not apply another manufacturer’s similar B2 code.
At 11.0592 MHz, 20 ppm is about 221 Hz. This is the initial tolerance at its specified test condition and should be budgeted separately from temperature stability. If a communications link depends on the combined error of both ends, check the remote clock and total margin before widening the grade. Have engineering confirm any relaxed environmental limits.
At receipt, compare the manufacturer's package label with the order and sample frequency at the specified load and temperature. If the top marking omits the full code, retain the original reel label and split-lot reference. Near-identical room-temperature readings do not establish the ordered grade. Quote default and specified options separately.Abracon ABLS ordering diagram · Specific B2 configuration