Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Does a 38 Ω result prove that an ABLS 40 MHz crystal is a fundamental-mode part?

An incoming report lists an Abracon ABLS crystal at 40 MHz with 38 Ω equivalent series resistance. Someone concludes that it is a fundamental-mode part because the resistance is below that row’s limit. At 40 MHz, the series drawing covers both fundamental and third-overtone configurations, and both ESR figures are upper bounds. One measured value can be below either limit. The full order configuration, specified mode, and measurement conditions are needed for a usable sourcing decision.

A single nominal frequency can belong to two modes

The Abracon ABLS drawing lists frequency bands by mode. Part of the range above 24 MHz is listed for standard third-overtone operation, with a separate range for optional fundamental operation. The overlap includes 40 MHz. This applies to the ABLS family and does not carry over automatically to suffixes or lower-profile families. If an order merely says “SMD HC-49, 40 MHz,” specify the exact part and the mode the circuit uses. A family cover page or maximum advertised frequency does not settle those details.

A third-overtone crystal operates in a mechanical vibration mode. Harmonics seen when measuring a distorted waveform are a different phenomenon. If the scope or analyzer shows a 40 MHz component, inspect the acquisition, test circuitry, and other peaks before treating it as proof of the mechanical mode. The incoming record should say what resonance it measured. A system test should establish whether the approved circuit starts in the required state. When records are missing on a repair part, preserve the label, lot, and board revision and ask the supplier for its original configuration.

Understand what the 38 Ω figure establishes

The ABLS ESR table has a 40 Ω maximum in the fundamental row covering 40 MHz and an 80 Ω maximum in the third-overtone row. Under conditions applicable to the respective limits, a hypothetical 38 Ω result is 2 Ω below the first maximum and 42 Ω below the second. Passing one numerical comparison cannot identify a mode. A 46 Ω reading under the conditions for the fundamental specification calls for investigation if measurement uncertainty does not account for the gap. It does not, by itself, prove that the supplier shipped the overtone option. It may reflect a failed sample or mismatched measurement conditions.

Suppose two reports for 40 MHz crystals both give 38 Ω. One includes the full ordering configuration and a defined fundamental measurement. The other lists only a resistance and an instrument model. Ask for the measurement definition, load and drive conditions where applicable, and the corresponding limit. A comparison of two bare ESR values is not evidence that one crystal will start more readily in the actual circuit.

If the test covers drive-level dependency, retain both the peak ESR and its spread over the specified range. The drawing has separate limits for these quantities. With a 40 Ω maximum, 25 percent is 10 Ω. Three illustrative readings of 34, 38, and 42 Ω span only 8 Ω, but the 42 Ω reading still exceeds the 40 Ω maximum. The actual test needs the specified drive range and point count. A passing sweep and the correct ordered mode each need their own evidence.

Keep a mode test and a board test

Use a known fixture or a verified oscillator network. If examining a board spectrum, record the time-domain period and other peaks so a large harmonic is not mistaken for the operating frequency. For incoming inspection, ask for frequency and resistance evidence for the ordered mode. A verified board startup remains valuable system evidence, but it does not supply the missing order code or a device-specific test report. Combining both avoids rejecting a part based on one observation made while loading a sensitive node.

Compare an approved unit and candidate over repeated starts at the same supply, temperature, and configuration. If the candidate sometimes fails, inspect mode, matching and probe loading. When frequency is correct but time to startup varies significantly, investigate low-drive behavior and the test conditions. An ESR measurement at one operating point does not replace repeated cold starts and temperature qualification.

Put the electrical choices into the order

Record the full part number, 40 MHz nominal frequency, fundamental or third-overtone mode, load capacitance, ESR maximum, temperature range, and drawing revision. Pair that with mode-specific device evidence and board startup evidence. If an order template comes from an earlier 20 MHz passive crystal design, check which fields now need explicit values in the mode-overlap band. For a substitute, obtain its own applicable manufacturer specification before evaluating samples. The next 38 Ω report can then be assessed against a known requirement with a clear next step.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.