Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Passive Crystals and Oscillator Circuits

Why does Abracon's ABM8 model use pF for one capacitance and fF for the other?

A 24.576 MHz audio prototype gets a crystal model, and the simulated impedance minimum appears close to 778 kHz. Check the capacitance units before changing the circuit. In the Abracon report, the motional capacitance for this ABM8 configuration is 2.54 fF, or 0.00254 pF. An entry of 2.54 in a field labeled pF makes the motional capacitance one thousand times larger. A quick calculation and an impedance sweep can expose the mistake before a board build.

Copy the circuit as well as the numbers

The model report, pages 10–11, identifies part ABM8-24.576MHZ-10-1-U-T. The five-sample averages are 0.79 pF for shunt capacitance C0, 2.54 fF for motional capacitance C1, 16.49 mH for motional inductance L1 and 8.74 Ω for the motional branch resistance R1. In its diagram, C0 goes directly across the two crystal terminals. The other branch connects R1, L1 and C1 in series. The report's specified 10 pF load is a frequency condition to implement as an effective external load when the test requires it. Put each capacitance in its own part of the circuit. Abracon crystal parameter test and SPICE model report, pages 10–11.

In SI base units these three reactive components are 7.9 × 10−13 F, 2.54 × 10−15 F and 1.649 × 10−2 H. C0 is about 311 times C1. If the simulator accepts engineering suffixes, verify what it does with the suffix and preserve the expanded value. A schematic editor can display one unit while a spreadsheet stores another. Record the units as part of an imported component's parameters.

Use the resonance to test the import

The report gives fs = 1 ÷ [2π√(L1C1)] for the motional branch. With the published averages the series resonance is approximately 24.59195 MHz. Enter 2.54 pF with the same inductor and the frequency becomes 1 ÷ √1,000 of that result, or about 0.77767 MHz. Entering 16.49 H in place of 16.49 mH would give the same large error, so examine both inputs when the simulated minimum is an order of magnitude off.

Sweep the crystal model on its own before adding the host oscillator. Look for a low-impedance region near series resonance and the higher-impedance antiresonant region. The lossless estimate fa ≈ fs√(1 + C1 ÷ C0) is approximately 24.63145 MHz with these inputs. An otherwise sensible series resonance with an unexpectedly placed antiresonance provides a reason to check the units, terminals and location of C0. Save the standalone impedance sweep so it can be compared with the same model once the board and input parasitics are added.

If the measured and simulated traces still disagree, check the fixture reference plane and compensation. Keep the markers for series resonance, antiresonance and test drive together. Adjusting R1 may change the depth of a dip, while a mistake in C1 can move its frequency substantially.

The calculation from rounded, separately averaged motional parameters is a scale and topology check. The nominal 24.576 MHz in the report refers to a specified load. A model created this way may be inadequate for predicting an error of a few hundred hertz. When that precision matters, request more precise matched parameters for one measured sample, or characterize that sample on a calibrated fixture at the stated conditions. Avoid changing a model parameter merely to force agreement with the carrier marking.

Keep model statistics separate from the buying limits

The reported sample ESR averages 8.74 Ω and reaches 10.53 Ω among the five tested pieces. The same report lists a 50 Ω ESR limit. The ABM8 family data sheet also puts 50 Ω maximum in the standard 20.000–29.999 MHz fundamental band. For a design margin or purchasing decision, confirm which guarantee and temperature range apply to the exact order code. When checking drive, the test report's 10 µW maximum during characterization is its measurement condition. Obtain the part's operating drive rating in the approved technical documentation. Abracon ABM8 series data sheet, standard ESR and ordering options.

Abracon reports an average load sensitivity of 10.94 ppm/pF for the measured samples. Near the 10 pF condition, a hypothetical 0.5 pF increase in effective load gives a local estimate of 5.47 ppm downward, or about 134.4 Hz at 24.576 MHz. This is useful when planning capacitor trials. The ±10 ppm frequency window in the test report would correspond to ±245.76 Hz at the nominal frequency. Keep those figures in different columns. The first concerns a modeled change and the second concerns acceptance at the specified load, temperature and drive.

For startup work, first understand the circuit with a representative model, then test the guaranteed resistance range and the board's parasitics. When varying motional inductance and capacitance for a model intended to remain near the nominal frequency, check that their product still represents that frequency. Model stress cases with independently forced extremes should be marked as such. Store the simulation values, quoted part number, documentation revision and board startup record together. A quote for a similarly named configuration can then be compared on load, package and guaranteed limits before anyone decides to reuse the original model.