A repair team replaces the reference on a dual-rail networking board. The new part locks normally. In standby, a load switch removes power from the oscillator while the receiver remains on an always-powered rail. The switched oscillator rail retains some voltage, and purchasing suspects a defective three-state output. Abracon's LVDS ABNM specifications cover three-state behavior and power-off output leakage separately. Use this 125 MHz differential quartz oscillator as a maintenance example and evaluate each limit under the applicable voltage conditions.
Establish which state the manufacturer tested
The ABNM family includes LVDS, PECL and CMOS. The electrical tables depend on the output format. A 125 MHz LVDS order falls within the 125.000 to 156.999 MHz band. Its table lists power-off output leakage Ioxd of about ±1 µA typical and ±10 µA maximum. The condition specifies an output voltage setting and VDD at zero. That line does not cover every possible receiver bias. Obtain manufacturer confirmation for the actual terminal voltage, current direction and power state before using it as a board guarantee. The data sheet also marks ABNM as end of life. It is a maintenance example. Apply each replacement candidate's own specifications.
For the LVDS version, the pin function table identifies low on pin 1 as three-state. That operation controls the output with the device powered. An equipment standby sequence can involve active output with supply present, three-state with supply present, or removal of oscillator supply. The second state cannot establish leakage in the third. Document which rail is present, which receiver and terminations remain biased, and where leakage and residual voltage are measured.
A small current can raise a high-impedance rail
Suppose a powered-down rail has an effective 47 kΩ discharge path to ground. If a measured current of 10 µA enters it and the behavior is approximated as DC and linear, the residual voltage is 0.47 V. If two separate paths each contributed 10 µA in the same direction, it would be about 0.94 V. This illustrates why a small current can matter. An output leakage number cannot be summed into a guaranteed system backfeed current without establishing the paths. Actual termination, input clamps, contamination and the load switch can contribute.
Before the power-off test, establish a normal clock baseline. Verify the 125 MHz LVDS configuration, supply and intended load while the system is fully powered. Record the differential clock and receiver lock. In the power-off check, separate removal of oscillator supply from removal of receiver bias. A scope input can itself provide a DC path. Use appropriate high-impedance observation and record connections, disconnect points and applicable protection for the devices under test.
Specify the power-off condition on the replacement order
Compare an approved original on the same board revision under three conditions: active output, powered three-state and source power removed. Confirm the sequence both without and with applicable receiver bias. Record both supply rails, the two clock pins and residual voltage versus time. If the rail rises only when receiver bias is added, inspect the termination and clamp paths. If residual voltage occurs with both clock lines disconnected, investigate the switch, filter and other supply paths. Obtain applicable terminal test conditions before applying an external DC voltage to an unpowered output.
A timed measurement can help distinguish a lifted rail from one still discharging. Suppose the rail has only a 47 kΩ path and 10 µF with no current entering. The linear model gives a 0.47-second time constant. After about five time constants, or 2.35 seconds, less than 1% of the starting voltage remains. A persistent voltage that falls only after receiver bias is removed provides a reproducible clue. Actual capacitors and leakage paths can differ. A trace ending a few tens of milliseconds after switch-off cannot by itself distinguish ordinary discharge from receiver backfeed.
When comparing candidates, use the same set of board states and retain each exact part number. Identical three-state behavior does not establish identical behavior with receiver bias and different power sequencing. Establish safe, applicable terminal conditions with engineering and the supplier. When retaining evidence from an old repair assembly, check that it pertains to the same output format.
In the purchasing attachment, record the supply states, actual receiver bias, allowable leakage and residual voltage, and measurement time. A candidate 125 MHz differential oscillator lacking an applicable guarantee can be evaluated while engineering checks whether existing isolation or sequencing resolves the gap. Release the exact current candidate after the required operating states pass. An acceptance record for powered three-state needs a separate entry for any power-off bias requirement.