An older board uses the Abracon AK7DBF1-125.0000T2. The service team finds another AK7 with the same size and apparent frequency. If the candidate relocates output enable from pin 1 to pin 2, pulling the old board's pin 1 low may leave the clock running. For a 125 MHz differential oscillator, specify the enable position in the supplier confirmation, fixture wiring and system stop-clock test. A normal frequency reading at power-on can miss this difference.
Read the enable location from the ordering field
The AK7 ordering guide separates output type, supply, stability and enable function. In AK7DBF1-125.0000T2, D denotes LVDS, B denotes 2.5 V, and F gives the ±25 ppm temperature stability grade over −40°C to +85°C. Code 1 is active-high enable on pin 1. T2 means 250 per reel. A candidate with enable code 3 puts active-high enable on pin 2 and leaves pin 1 as no connect. Obtain confirmation of the complete proposed combination rather than treating the option list as a commercial availability statement.
Both connections use pin 3 for ground, pins 4 and 5 for differential output, and pin 6 for power. A fixture using only those four pads can see the same running clock. Trace the legacy board's enable net to the actual device pad and inspect the fixture wiring. The family drawing shows a representative pin 1 test circuit with a note covering the alternate position. A copied fixture can send the correct logic sequence to the wrong physical pin 2 variant.
Check control voltages and timing at the component
AK7 defines enable high at a minimum of 0.7 times supply and low at a maximum of 0.3 times supply. The 2.5 V grade lists a 2.37 to 2.62 V range. High must reach 1.834 V at the upper supply limit, and low must remain at or below 0.711 V at the lower limit. If the controller guarantees only 1.8 V high, it misses the adverse high limit by 34 mV. Operation at nominal supply does not cover that case. Measure a level translator at its real load and verify which pad is driven during start-up and reset.
The sheet lists a maximum 0.2 µs output-disable time and a maximum 5 ms enable time. If a system needs the clock off within 200 ns of its command, the disable specification consumes that entire interval before adding board logic or measurement location. Capture the command event and the point where the actual oscillator pin reaches a valid low. Controller logs alone do not describe the electrical timing. A shorter system restart budget also needs its own tighter evidence or a timing change.
Put the package orientation in the first-article record. A fixture may be drawn from the pad side while incoming photographs show the top. A mirrored copy can miswire even an already confirmed option. Establish orientation from the shared ground, supply and differential outputs, then verify the enable pads and fixture probes. On a legacy fixture without a drawing, verify continuity with power removed before applying power. Record supply at pin 6 and the enable voltage relative to pin 3 to reconcile actual wiring with the program.
The disabled supply-current entry has a narrower test condition. High impedance uses a low threshold of 0.3 times supply, while the below-10 µA entry separately specifies enable at or below 0.3 V. At 2.5 V, pulling enable to 0.5 V may turn off the output while leaving the current guarantee untested. Put both input conditions on the order when shutdown and low current both matter. Measure under the specified low voltage and then separately verify the real board, including whether other components share the metered supply.
Exercise both the fitted configuration and the fixture
At first article, keep the specified supply and drive the correct pin high. Check the 125 MHz waveform at the 100 Ω differential load, then drive low and verify that periodic output stops. Confirm that the fixture does not drive the unused pad. For an unidentified version, recover the label and orientation and resolve the two pin functions with the supplier before applying stimulus. Receiver bias can leave a DC voltage after the source stops. Use the approved load and record the measurement point, threshold, current protection and timing.
On the service order for this 125 MHz differential oscillator, specify pin 1 enable and pin 2 no connect, with confirmation against the full number and applicable data sheet. Create a separate approval for the board that actually uses pin 2. If a delivery label only gives AK7, hold it for evidence or follow an approved first-article identification procedure. That preserves the intended stop-clock behavior on two assemblies whose continuous output could look identical.