Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / System Validation and Replacement

Why do edges disappear when an AC-coupled clock slows down?

A differential input works at full speed. In low-frequency maintenance mode, the scope shows a brief pulse near each transition and the receiver sometimes misses a count. The wiring and nominal levels are the same. Each high and low interval now lasts longer. In an AC-coupled link, the series capacitor and surrounding resistances form a high-pass network. During a long interval, the receiver voltage can decay toward its own bias before the next transition.

Start with the high-pass corner

Renesas AN-844 explains that the lowest spectral content the link needs to preserve should lie well above the coupling network's cutoff. The AC-coupled receiver uses internal or external DC bias. Both sides may have correct DC conditions and the capacitance can still be too small to preserve pulse widths. Digital inputs need the waveform to stay beyond the high or low threshold long enough. Even with clean transitions, a level that decays into the undefined region before the next edge can shorten the received pulse.

Draw the AC small-signal circuit. Combine source impedance, receiver bias, and termination as seen by the capacitor to find the time constant. For a symmetrical pair, use the specified differential equivalent or a half circuit. Two series capacitors do not justify multiplying one capacitor by the entire differential resistance without simplifying the network. Vendor recommendations can specify how an AC reference is bypassed, whether bias is buffered, and whether there is a separate differential termination. Each changes the impedance. A long transmission line adds separate effects, so model the part of the path being compared.

A cutoff calculation for a sine wave is a starting point. Edge speed generates higher-frequency content, while the fundamental and burst envelope influence low-frequency behavior. A continuous clock near 50% duty cycle is easier to pass than a few pulses separated by a long interval. After checking continuity at steady state, test mode changes, stops, and restarts. During a long disable interval the receiver normally returns toward its local bias, so the capacitor charge at the next burst differs from continuous operation. Reproduce this with ordinary hardware power and enable, and document the startup state.

Estimate how much of the level remains

Suppose a simplified single-pole model gives 100 Ω seen by a 10 nF series capacitor. The time constant is 1 µs and the corner is about 159 kHz. Between transitions the voltage relative to bias decays exponentially. At 1 MHz the half period is 0.5 µs, so about 61% of the initial deviation remains at its end. At 10 MHz the half period is 0.05 µs, leaving about 95%. These are ratios within an interval. Actual swing also depends on the driver, termination, and steady capacitor charge.

If the 1 MHz mode can tolerate at most 5% droop, the same model needs a time constant of about 9.75 µs or more. With 100 Ω unchanged, the candidate is near 100 nF. Check minimum effective capacitance at operating bias, mismatch across the pair, and the receiver thresholds. A larger capacitor may pass lower frequencies and take longer to settle after a burst begins. Where the first edge matters, steady-clock results alone do not approve the change.

For a comparison, hold source waveform, termination, and probe conditions fixed. Record receiver bias, differential voltage, and logic decision. Sweep the project frequency range in continuous mode, then send a short burst after the real sleep interval. Capture the slowest mode and longest high and low intervals. If a programmable drive setting already reduced the source amplitude, correct it first. If the source stays the same and the decay time scales with capacitance, investigate the coupling network.

When an interface change makes more sense

Increasing capacitance may not cover every mode. If the clock stays static for a long time and the receiver must know whether it was held high or low, series capacitors cannot convey that DC state. If both sides' common-mode, differential, and DC supply conditions allow it, evaluate DC coupling using the manufacturer circuit. Another option is a clock translator or gate that explicitly supports the input mode. Give purchasing and the supplier the minimum continuous frequency and longest stop as well as the maximum frequency.

Record trigger conditions for continuous operation, wakeup, and entry into the slow mode after reset. Compare swing and pulse widths at consistent receiver thresholds. A fixed absolute threshold and a different percentage-of-swing threshold cannot be compared directly. This helps distinguish an instrument's frequency-reading behavior from a real lost pulse as the receiver level decays.

When using a smaller capacitor package, verify minimum effective capacitance at low temperature and operating bias. Similar size and nominal value do not guarantee the same result. Document the nominal value, worst-case estimate, and operating conditions next to the slow-mode measurement.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.