A motor-monitoring prototype recorded at a high rate in the lab. In the field, a lower rate saves storage, but a new low-frequency peak appears even though motor speed has not changed. Before improving the sampling oscillator, find the changed setting. Did the sensor's output data rate change, or did the host start saving every few readings? Both reduce file size, but they act at different places and can affect the spectrum differently.
Output data rate, or ODR, is how often the sensor prepares a new sample. A digital accelerometer can acquire internally, filter, and decimate before the host sees its output. Filters change amplitude and delay. The host may then store or downsample the data again. A thread running 1,000 times per second does not establish that it sees 1,000 new samples. Repeated reads of one register value can be incorrectly marked as distinct points on a plot.
Follow a 700 Hz test tone through the reduction
Assume the sensor delivers 4,000 valid, distinct samples per second with a 700 Hz component. The host keeps every fourth point without filtering first. The file now has 1,000 samples per second, and the tone can alias to 1,000 − 700 = 300 Hz. Check the decimation step if the new peak matches that calculation. A tighter clock might adjust the scale slightly. It would still leave the 700 Hz component free to alias.
If the ODR was changed at the sensor itself, check the device's processing. The ADXL355 datasheet describes how analog and digital decimation filters determine the passband and provides delay at several output rates. Reducing ODR can alter both bandwidth and delay. That differs from discarding high-rate samples at the host. Sweep the range of interest on a reliable vibration source. Use the same reference sensor to confirm the input and compare amplitudes, output, and event timing. Control the mounting fixture so that a mechanical resonance is not mistaken for a digital effect.
Define which fault the customer needs to see
Some users only need to monitor shaft speed and can discard much higher frequencies. For brief impacts, high-frequency content, time resolution, and event latency matter. For the ADXL355 settings at 4,000 Hz and 1,000 Hz, the datasheet lists digital filter group delays of about 0.63 ms and 1.78 ms, respectively. The difference is about 1.15 ms. Those figures cover specified filter settings, not the whole latency of an installed system. If two sensors locate an impact by timing and only one changes ODR, check processing latency even if both sets of timestamps are accurate.
Record a high-rate file, then downsample it offline with and without an anti-alias filter and compare both with the sensor's direct low-rate output. If only the unfiltered reduction creates the peak, focus on that step. If the original high-rate file already contains the same component, check the mechanical cycle, fixture stiffness, and supply interference. Align the file rate, measured sensor ODR, and FFT scale. Labeling data sampled at 4,000 points per second as 1,000 shifts every peak proportionally. One aliased component has a different signature.
For a replacement, purchasing can specify vibration band, maximum event latency, data volume, and output interface. A "1,000 Hz sensor" can mean a 1,000 Hz ODR or a 1,000 Hz useful bandwidth. Ask for the exact setting, filter response, and delay from the manufacturer. Include a steady tone, a short event, paired comparison, and a long run in acceptance, retaining the high-rate file. If a peak moves after slowing down, trace which data stage changed and decide whether the part specification or processing needs attention.
For an unattended monitor, save the actual configuration and sample counters in the record. Mark missing points and decide whether that interval is usable. Silently filling a gap at the nominal rate can reshape a real start or stop into apparent frequency content. For phase comparisons, apply a common, timed transient and compare event position and uncertainty. Repeat at a lower vibration frequency to check how the difference depends on filters and input band. Keep the results by mode rather than applying one delay correction to all settings.