An industrial servo test rig worked in the 12-bit position mode. After a switch to 16 bits, the stationary readings look finer, but the angle error grows during motion. The master reference still reads 8.192 MHz. Check both the excitation and the configured resolution. A single crystal can produce different excitation frequencies, and the recommended ranges at 12 and 16 bits only partly overlap. Tracking bandwidth and speed also merit a fresh check.
Locate the change with the excitation word
The AD2S1210 generates sinusoidal resolver excitation with a programmable frequency control word. The nominal excitation is the word multiplied by CLKIN and divided by 32768. An 8.192 MHz quartz crystal makes the step 250 Hz. Decimal 40, or 0x28, produces 10 kHz. Decimal 48, or 0x30, produces 12 kHz, with no change to the crystal.
The manufacturer's recommendations for 8.192 MHz CLKIN list 6–20 kHz in 12-bit mode, 3–12 kHz in 14-bit mode, and 2–10 kHz in 16-bit mode. A 12 kHz setting therefore leaves the recommended range when the system moves to 16 bits. A 9 kHz setting, from word 36, sits within the overlap of all three modes. Check that the resolver and the excitation and input-conditioning hardware also support that frequency. The converter's table does not specify the whole system.
If engineering considers using a 10.24 MHz reference, word 40 gives a nominal 12.5 kHz and the step becomes 312.5 Hz. Word 32 gives nominal 10 kHz. This only calculates excitation frequency. Verify the timing and tracking requirements again, including the conditions attached to tables using the original reference. Allow for the oscillator's frequency tolerance when checking the input clock limit.
Prove static resolution and dynamic accuracy separately
A 16-bit output divides one electrical revolution into 65,536 codes, about 0.00549 degrees per code. A 12-bit output uses 4,096 codes, about 0.08789 degrees per code. Those are quantization intervals. Accuracy also depends on signal amplitude and phase, mechanical installation and the tracking loop. Under the data-sheet conditions, the typical loop bandwidth at 12 bits is 1,700 Hz. At 16 bits it is about 250 Hz. Check velocity and acceleration against actual system requirements.
On a bench, hold the resolver at a known angle and record distributions, means and error flags in both resolutions. The ADI reference circuit uses a fixed-position histogram to assess system noise. For the dynamic test, use an independent position reference and observe the error as speed rises. Capture the excitation, sine and cosine signals during that run. If the anomaly occurs only outside the recommended excitation range, repeat under an approved combination while keeping temperature and mechanical load comparable.
Document how the test handles wraparound and timing. For example, a reference of 359.98° and a measured angle of 0.03° differ by +0.05° around the shortest arc. Plain subtraction produces −359.95°. Compare both values in the same electrical angle frame before reporting peak error.
The falling edge of SAMPLE transfers the internal estimates into the position and velocity registers. Log that edge separately from the serial readout. At ten mechanical revolutions per second, a 100 µs alignment error between the DUT and reference is 0.36° mechanically. That can dominate the resolution being compared. Align the reference and device on the same acquisition time and document how electrical angles correspond to mechanical angles.
Document both the mode and the clock connection
In normal mode the resolution depends on the RES0 and RES1 pins. In configuration mode it comes from the corresponding control register bits. Check that these agree when switching modes. Record the frequency control word, pin states and measured excitation. Also verify how the host scales the codes. A mismatch in the host can survive both a correct register write and a clean oscillator waveform.
For an 8.192 MHz passive crystal, confirm the crystal-pin connection, specified load, ESR and startup. If using an 8.192 MHz active oscillator with a single-ended output, apply a suitable signal to CLKIN and leave XTALOUT unconnected as directed by the data sheet. Verify the input timing, levels and supply. Procurement can retain the full order code and operating conditions. Engineering should attach the clock circuit, the excitation word, both resolution settings and the dynamic test results. That record gives both teams a basis for deciding whether the next step is component qualification or board and firmware work.