Two counters read 125 MHz after every power-up, but an acquisition card starts half a cycle earlier on some runs. Put both clocks on a scope with a shared trigger. The counter tells you how often each output repeats. The scope can show where one edge lands relative to the other. Each AD9528 output divider counts separately, so check whether both dividers saw the same synchronization event, which delays were programmed and where you are measuring.
Find the divider that actually participates in SYNC
Map the board connectors to OUT0 through OUT13. Read the source, divider field, digital coarse delay, fine-delay enable and output mode for both channels. The AD9528 distribution paths include PLL2, PLL1/VCXO and SYSREF. Output synchronization resets the eight-bit channel divider, so the clock must take that path for the procedure to apply. If a channel carries SYSREF, check that SYSREF is resampled by the channel divider output before treating it as a participant. Two measured frequencies can agree while the clocks take different paths. ADI clock distribution paths and synchronization conditions
For a numerical example, a 3.500 GHz PLL2 VCO and M1=4 give 875 MHz at the channel divider input. Dividing by seven on OUT3 and OUT8 gives 125 MHz on both. The register encodes the divisor minus one, so write a divider field of six for each. ADI calls for a sync command after changes to the divider value or digital coarse delay so the intended setting takes effect at the output. Equal sources and divider settings establish equal periods. Measure where the edges land. ADI dividers, coarse delay and sync · ADI divider field encoding
Check both Ignore SYNC bits and both software transitions
OUT3 uses bit 3 of 0x032B and OUT8 uses bit 0 of 0x032C. For either bit, zero participates and one ignores the command. The second register also holds the PLL2 N2 feedback-divider ignore bit. Change the target channel bits while preserving the other channels and the N2 setting. ADI Table 59, channel and N2 controls · ADI Table 59 continued, OUT8 control
- Save the current configuration and check that PLL2 is ready and locked. Clear Ignore SYNC for both test channels and program their divider and delay fields. Issue
IO_UPDATEthrough bit 0 of0x000Fto apply buffered configuration. - Set bit 0 of
0x032Aand issueIO_UPDATE. Participating outputs are temporarily disabled while the sync bit is active. Capture both outputs to see that interval. - Clear the same bit and issue
IO_UPDATEagain. The active1→0transition issues the sync. Writing one and then zero before a single update can leave only zero in the active register. Use a bus trace or a controller marker to align the two updates with the observed output edges.
The first PLL2 lock after power-up or reset automatically synchronizes the channel dividers. A later unlock and relock does not redo that sequence unless the device goes through the power-down or reset conditions in the datasheet. For a startup test, record the PLL2 lock and sync events. For recovery in service, check separately whether the firmware issued a sync request. ADI first-lock behavior and software sync · ADI buffered writes and IO_UPDATE
Translate 125 MHz phase into a time difference
A 125 MHz period is 8 ns. Define Δt as the OUT8 edge relative to the OUT3 edge, reported in a window from zero up to 8 ns. Suppose the first restart gives 0.30 ns and the second gives 4.30 ns. The 4.00 ns change is half the period, or 180°. Those readings illustrate a run-to-run change and cannot identify the cause on their own. Capture both clocks on a common trigger at the same receiver test points, deskew the probes and compare the traces with the path, update sequence and ignore settings.
If the offset stays near 0.30 ns over restarts, check fixed channel delay, routing and the measurement chain. At the 875 MHz divider input in the example, half a period is about 571 ps. Adding two coarse delay steps gives about 1.143 ns nominal, or 51.4° at 125 MHz. The coarse step uses the divider input period. Analog fine delay also adds a nominal insertion delay when enabled at code zero. Keep track of which channels have it enabled before making an adjustment and rechecking at the receiver. ADI coarse step size and fine-delay insertion
Test initial alignment and resynchronization in service separately
On the bench, run a software sync with both channels participating. Save the outputs before, during and after it. Then set only OUT8 to ignore and repeat with the other settings held constant. If OUT8 still shows a gap, check its source, PLL2 status and output controls. If neither output shows a gap, check whether the update reached the device and whether the probed connectors are the intended channels. Restore the production settings and repeat the startup test several times.
At startup, synchronization can finish before the downstream interface begins running. In service, measure whether the receiver tolerates the clock gap. If two successive observed rising edges are 40 ns apart on a clock with an 8 ns normal period, the interval is consistent with four expected rising edges missing. Record the gap, recovered phase, any lost frames and whether the receiver needs reinitialization. For a supplier or customer review, specify the chip and board revision, receiver test points, startup or relock scenario, timing window and acceptance capture. A frequency-only specification leaves the alignment requirement open.