Two labs measure different close-in phase noise from the same VCXO model. Both reports say “supplied 6 V adapter.” Ask for a photo of P9, P10 and P11. The adapter defines the input to the board. Between that input and the 3.3 V rail for the AD9528, the board can route power through an LDO, through a passive filter on the buck output, or directly from the buck. All three can give similar DC voltmeter readings while presenting different ripple, transients and spurs.
Read P9, P10 and P11 as a set
On the AD9528/PCBZ, ADI connects the 6 V adapter at P500. Two buck regulators in the ADP5052 generate the 5 V and 3.3 V supplies. Table 1 of the evaluation guide gives the three DUT supply paths. The numbers below are jumper positions in that table. Check the physical pin markings on your board. ADI evaluation guide, Table 1
| AD9528 DUT power path | P9 | P10 | P11 |
|---|---|---|---|
| 5 V buck feeding a 3.3 V LDO, default | 1, Enable | 1, LDO | 1, Filter |
| 3.3 V buck through passive filtering | 3, Disable | 3, Switcher | 1, Filter |
| Direct 3.3 V buck | 3, Disable | 1, LDO | 3, Switcher |
The last row is easy to misread. P10 sits in the position labeled LDO, while P9 disables the LDO and P11 selects the direct switcher path. Record the PCB revision, fitted jumpers and any rework before applying the table to an unfamiliar board. On sheet 5 of ADI drawing 02_037107, Rev. C, U2 is the ADM7150ARDZ-3.3 LDO. The sheet identifies the 3V3_DUT test point and the filter section with L5 and C89. It also shows dedicated USB and VCXO regulators. Check the DUT rail at 3V3_DUT and near the clock IC. The USB indicator or a reading at 3V3_VCXO checks a different branch. ADI Rev. C schematic, regulators and jumpers
Verify the rail before measuring phase noise
Power the board down before moving the jumpers, then photograph the new combination. Keep the other rails and reference cabling in their test configuration. After power-up, measure the DUT rail during startup, configuration load and enabling the intended outputs. Use an appropriate probe with a short ground connection, and keep the measurement point, bandwidth and capture time consistent. Changing the probe return can change the apparent spikes. If you are using an external VCXO, document its supply separately so any change there is visible.
The AD9528 datasheet gives 3.135 to 3.465 V for VDDx. Suppose the steady reading is 3.22 V but the scope shows a 100 mV dip when the outputs are enabled. That reaches about 3.12 V, 15 mV below the specified minimum. In this hypothetical run, investigate the rail, startup and probe setup before comparing phase noise. Once the rail stays in range, capture PLL lock status and the actual carrier so each test represents the same operating mode. ADI AD9528 supply voltage limits
Compare direct and filtered power from the same buck output
To see whether passive filtering helps at one spur, start with direct and filtered versions of the same 3.3 V buck rail. Rev. C shows L5=10 µH and C89=10 µF. The ideal LC natural frequency from 1 / (2π√LC) is about 15.9 kHz. The effective capacitance, losses, other decoupling and load determine the actual response. Measure ripple on the DUT rail to find the attenuation at the offset you care about. ADI Rev. C schematic, L5 and C89
Consider an illustrative result. With the same measurement bandwidth, a 600 kHz line on the power rail drops from 6.0 mV to 1.5 mV. That is a one-quarter voltage ratio, or about 12.0 dB lower. If the output spur at the same carrier offset drops from −72 dBc to −83 dBc, that is an 11 dB reduction. The matching offset gives you a place to investigate supply coupling. Other coupling paths still need to be checked. The example uses hypothetical readings and a hypothetical offset. Record discrete spur amplitude in dBc and phase noise density in dBc/Hz, with the relevant measurement settings.
Restore the default and take a fresh baseline
Start with the default LDO path. Save the board ID, jumper photo, voltage, PLL state and both the power spectrum and carrier trace. Then measure the filtered and direct switcher paths using the table. Keep the VCXO, reference, loop and output settings, output port and termination fixed. Use the same analyzer span, bandwidth, averaging and noise-floor treatment. If a line moves with the filter setting, look more closely at that offset. If the differences are comparable to the measurement floor or repeatability, record what the setup can resolve. Comparing the LDO path with the filtered buck also changes the upstream source from 5 V to 3.3 V, so report the result for the complete paths.
Restore P9/P10/P11=1/1/1, restart and measure again. If the first and last baselines differ, compare that drift with the difference between configurations and check thermal settling and cabling. For a customer design that uses a direct buck, run final acceptance on that topology at the actual temperatures and loads. Supply the board revision, full jumper settings, power measurements, carrier and instrument settings with the report. Mark which configurations were diagnostic and which represent the production board so both labs can reproduce the result.