Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Brands and Sourcing

Replacing an AD9545 50 MHz passive crystal with an active TCXO. Why does the system clock configuration change?

One AD9545 prototype uses a 50 MHz passive crystal. A proposed build has a same-frequency active TCXO. Both sources say 50 MHz, but the device's system-clock PLL uses a different input path for each. The Analog Devices data sheet allows input doubling on the crystal path and excludes the doubler on the direct path. The device also has separate inputs for external synchronization references. Before quoting the change, make sure the source to replace is on XOA/XOB and identify how the original setup generated the system clock.

Derive the feedback divider for each input path

In the crystal assembly, the 50 MHz passive crystal bridges XOA and XOB. The internal amplifier maintains oscillation, and the capacitors follow the crystal load requirement. Analog Devices specifies a fundamental-mode AT-cut crystal and tables motional resistance by frequency. A 50 MHz crystal falls in the range up to 52 MHz with a 100 Ω limit. Confirm actual drive power against the crystal manufacturer's limit. If the quote only gives package and frequency, request rated load, motional resistance, drive and temperature. The candidate crystal families in the AD9545 data sheet are starting points. Release requires evidence for the actual orderable part and circuit.

For a crystal build, confirm what the 10 pF figure describes. Under the manufacturer’s symmetric-network estimate, a 10 pF rated crystal and 3 pF of extra stray capacitance give about 14 pF for each tuning capacitor. A same-frequency crystal rated at 8 pF instead gives about 10 pF per side with the same assumed parasitics. Recheck crystal drive and frequency. Both values are starting points. Allow for component tolerance and layout and verify startup at the temperature extremes. Only the confirmed combinations of crystal and capacitors belong to an approved assembly option.

The data sheet puts the system PLL's internal oscillator between 2,250 and 2,415 MHz. As an example, enable doubling with a 50 MHz passive crystal, use an effective input divisor of one-half and set the feedback divisor to 23. The result is 2,300 MHz. A 50 MHz active oscillator on the direct path gives the same result with an input divisor of one and a feedback divisor of 46. If the assembly changes and the original feedback value of 23 is copied, the direct configuration with divide-by-one gives 1,150 MHz, outside the manufacturer's range. Calculate this during sourcing so both hardware and firmware can review the alternate.

These are frequency-planning examples. The first presents about 100 MHz to the phase detector. The second presents about 50 MHz with no prescaling. Equal internal frequencies still need phase-noise and spur comparisons. Analog Devices notes that low phase-detector input frequency can degrade phase noise and separately describes a low-noise configuration using the crystal path, doubler and a compensation method. If changing to an active source for long-term stability, retain the established noise test for comparison. Record the bandwidth, source and board revision. An equal reading on a frequency counter does not establish equal clock quality.

Measure swing where the active source meets the receiver

The manufacturer shows a 3.3 V CMOS TCXO or OCXO with a resistive divider and AC coupling into the self-biased input. For that connection, it gives a maximum swing of 1.14 V and an optimal swing around 800 mV peak to peak. An ideal 3.3 V swing through the example 649 Ω series and 221 Ω shunt divider gives approximately 0.84 V. Driver impedance, resistor tolerance, routing and probe loading affect that value. Ask for output levels and load conditions with the quote. Measure through the installed network on a first article to verify receiver swing. The oscillator supply label alone cannot establish it.

For the AD9545 evaluation board, Analog Devices describes an onboard 49.152 or 50 MHz crystal and jumpers selecting crystal, TCXO, OCXO or an external connector. When changing the cable, confirm the evaluation-board revision and jumper routing. Then check the software's crystal or direct selection and its declared system reference frequency. A single unchanged project file does not validate both assemblies. Keep any external synchronization references on their intended inputs so the two tests stay traceable to the right signals.

Tie acceptance to the installed configuration

Give the 50 MHz passive crystal and 50 MHz active oscillator their own material descriptions and approved assembly variants. The passive record carries oscillation mode, load and drive limits. The active record carries supply, output, temperature and the coupling and divider network. Save the selected path, feedback configuration and system lock and stability indication. Measure the downstream outputs in representative operating conditions. Capture cold startup, low supply and active-oscillator enable timing to check whether the source is stable before system PLL calibration.

Ask the lab to name the status field used for acceptance. Initial system PLL lock and an additional configured stability wait are separate events. If downstream operation must wait until the clock is stable, capture configuration, lock assertion and service startup on one timeline. A later test after an oscillator change can show whether the source took longer to start or whether the system timing needs review.

If the first article fails to lock, verify the installed source, jumpers, registers and input waveform before changing frequency accuracy grades. Once the network and settings have been verified, compare oscillator startup, swing, temperature behavior and noise to the purchase guarantee. Reference the approved assembly and clock configuration on the order. If the supplier offers a same-frequency alternate, that record shows whether it belongs in the crystal circuit or needs separate qualification on the direct path.

References

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.