With the signal generator settings unchanged, moving the cable to the adjacent reference input can leave the AD9545 unable to validate the reference. Start with the board’s analog input network. The manufacturer’s guide describes transformer coupling for the Type A inputs separately from the single-ended Type B inputs. It also specifies different default level treatment for the B and BB lines. Identical SMA connectors can feed different signals to the IC.
By default, REFB is intended for DC-coupled 1.8 V or 1.2 V CMOS and has a 50 Ω load to ground. REFBB has an on-board divider that attenuates 5 V or 3.3 V CMOS to the appropriate input level. Passing a low-swing source through unnecessary attenuation can prevent reliable threshold crossings. A high-level source also needs the correct attenuation path.
Verify the generator’s actual output under load, then trace the relevant input network and measure logic levels and usable edges at the IC. Match the software input type to the physical connector. If frequency is correct but validity remains false, check the expected reference frequency, validity criteria, and observation interval separately from input voltage.
Send the connector number, source termination settings, and actual IC input levels with a service report. A screenshot reading 10 MHz is insufficient for reproducing the setup. Verify each customer oscillator with the receiving path intended for its logic level, and record the measured high and low plateaus so another source can reproduce them.ADI AD9545 evaluation-board guide, Reference Inputs