Sizing jitter for a 100 MHz ADC clock: which frequency belongs in the calculation?

An acquisition board runs on a 100 MHz oscillator. Its sample rate stays fixed while the test tone moves from 10 MHz to 40 MHz, yet its signal-to-noise ratio falls. For the contribution from sampling-time jitter, use the analog frequency present at the ADC input. The 100 MHz figure describes the clock and sampling setup. Using the input frequency in the calculation helps engineering decide whether to investigate the clock, source or analog front end. It also gives purchasing a reason to ask for a specific jitter measurement.

Why time uncertainty becomes a voltage error

Plot a sine wave and compare two nearby times. Near a peak, an early or late sample yields almost the same voltage. Near a zero crossing, the slope is much steeper, so the same time difference produces a larger voltage error. For a single sine at frequency f and small random sample-time errors with an RMS value of tj, the SNR limit due to jitter alone is about 20 log10[1 ÷ (2πftj)]. Use hertz and seconds. The ADC contributes aperture jitter, the variation in its internal sampling instant. Time uncertainty on the arriving clock contributes to the same sampling error budget.

Assume the sample rate is 100 MSPS throughout and the total random jitter is 1 ps RMS. The following numbers are calculated limits for the jitter contribution and do not describe measurements from a particular board.

Analog inputJitter-limited SNRWhat it means for the test
1 MHzAbout 104.0 dBThe ADC's other noise can be the dominant limit
10 MHzAbout 84.0 dBThe same time error lowers this limit by about 20 dB from 1 MHz
40 MHzAbout 72.0 dBMeasure at the high end required by the application
80 MHzAbout 66.0 dBUse 80 MHz even if an undersampling setup displays a 20 MHz alias

An 80 MHz input sampled at 100 MSPS can fold to 20 MHz on the displayed spectrum. Confirm the ADC analog bandwidth, frequency plan and input filtering before using that band. The alias changes where the signal appears, while the slope at the sampling instant still comes from the actual 80 MHz waveform. Substituting 20 MHz would overstate the jitter-limited SNR by about 12.0 dB in this example. For a wideband or multitone input, keep its actual spectrum and bandwidth with the budget. A single-tone calculation does not predict all effects of signal or jitter spectrum.

Work backwards from the SNR to the timing allocation

Suppose the design needs to sample a 20 MHz input and allocates 80 dB to jitter alone. The equation gives a total limit of about 0.796 ps RMS. If the ADC aperture jitter is assumed to be 0.50 ps RMS and is uncorrelated with the other random sources, the remaining external allowance is √(0.796²−0.50²), or about 0.619 ps RMS. This is the whole external path, which can include a PLL, clock distribution and noise at the receiving threshold. Check that the contributors are quoted using compatible definitions, integration limits and measurement points. A common reference, correlated sources and periodic disturbances need treatment appropriate to the actual circuit.

Now suppose the system as a whole must achieve 80 dB and the independent noise sources apart from jitter amount to 85 dB SNR. An 80 dB jitter contribution and an 85 dB contribution from other sources add as noise powers relative to the signal. The result is about 78.81 dB overall. To reach 80 dB with the same other noise, allocate about 81.65 dB minimum to jitter. The total timing allowance is then about 0.658 ps RMS. Retaining the illustrative 0.50 ps aperture contribution leaves about 0.428 ps for the external path. If a buffer independently takes 0.20 ps, the remainder is about 0.378 ps for the rest of the path. Use the actual ADC specification and board evidence before converting an example into an ordering limit.

Ask for the integration band and measure at the receiver

Request the exact oscillator configuration, output logic, supply, load and phase-jitter integration limits. A value expressed as peak-to-peak jitter, a cycle-based interval and a band-integrated phase jitter in RMS units describe different measurements. Compare equivalent definitions. A PLL or clock buffer between the oscillator and ADC can reshape the timing-noise spectrum. Record where the measurement is taken, the lower and upper offset frequencies and how discrete spurs are treated. Supply and signal disturbances near the ADC input threshold can also move the apparent timing edge, especially when the arriving transition is slow.

If the oscillator meets its phase-noise specification but the board still fails, make a separate estimate at the receiving threshold. Assume a clock slope of 1 V/ns at that point and 0.5 mV RMS of equivalent threshold noise. A first-order estimate gives 0.5 ps RMS of timing error. At 0.5 V/ns the same noise gives about 1 ps. Probe the buffer output and the ADC input with appropriate loading, and document bandwidth and supply conditions. Identify where the disturbance comes from before adding it as an independent contributor. An edge-jitter measurement taken at the receiving pin can already include it.

Test at least two analog frequencies on the same board. Keep the signal amplitude, sample rate, FFT window, measurement bandwidth and source setup comparable. Report whether the metric is SNR or includes distortion as SINAD. Change one part of the setup at a time to see whether the high-frequency result follows the source or the clock. At a low input frequency the converter or front-end floor may dominate. Keep the ADC model, clock tree, actual analog test frequencies, oscillator ordering code and spectra with the qualification record. That record lets purchasing compare comparable parts and lets engineering determine which stage to improve.

Analog Devices MT-007, page 4, aperture jitter derivation. Analog Devices AN-835, high-speed ADC testing methods.