Should ADF4351 N be calculated from the VCO or output connector frequency?

The target is 915.200 MHz. The board has a 40 MHz reference, and the software says N=183.04. A technician divides the connector frequency by the 20 MHz phase detector frequency and gets 45.76. It looks like the firmware is off by a factor of four. First check where the ADF4351 takes its feedback. Both values can produce the same connector frequency when used with their own feedback paths.

Label the connector, VCO and input to the N divider

Use separate names for the reference input fREF, the phase-frequency detector frequency fPFD, the internal oscillator frequency fVCO and the main output fOUT. Call the RF output divider ratio K, so the main output frequency is fVCO / K. Calculate the reference path as fPFD = fREF × (1 + D) / [R × (1 + T)], with D as the reference doubler bit, T as the reference divide-by-two bit and R as the reference counter. A 40 MHz reference with R=2 and D=T=0 gives 20 MHz at the detector. ADI reference-chain equation and synthesizer example

R4.DB23 selects the source for the N divider. With the bit set to 1, feedback comes from the VCO fundamental. In lock, fVCO = N × fPFD, so fOUT = N × fPFD / K. With the bit cleared, feedback comes from after the RF divider, so fOUT = N × fPFD and fVCO = K × fOUT. In either case, N = INT + FRAC/MOD. Record R4.DB23 alongside R4.DB22:DB20, which select the output divider. A divide-by-one test can pass with either formula because the VCO and connector frequencies are equal in that case. ADI R4 feedback and output-divider settings

Check the math with ÷4 and ÷2 outputs

The ADF4351 VCO operates from 2.2 to 4.4 GHz. Multiply the desired main output by the selected K and check that the result is in that range before calculating N. The following examples keep fPFD=20 MHz and MOD=1000 to show how the feedback path changes the integer and fractional terms. ADI VCO range and INT, FRAC and MOD limits

Main output / dividerFeedback sourceCalculated VCON and its fieldsPrescaler
915.200 MHz / ÷4VCO fundamental3,660.800 MHz183.04, INT 183, FRAC 408/9
915.200 MHz / ÷4After RF divider3,660.800 MHz45.76, INT 45, FRAC 7604/5
1,380.400 MHz / ÷2VCO fundamental2,760.800 MHz138.04, INT 138, FRAC 404/5
1,380.400 MHz / ÷2After RF divider2,760.800 MHz69.02, INT 69, FRAC 204/5

In the first row, multiply 183 + 40/1000 by 20 MHz and divide by four to get 915.200 MHz. In the second, multiply 45 + 760/1000 by 20 MHz to get the same main output. Pair that second N with fundamental feedback, though, and the math puts the VCO at 915.200 MHz, outside its range. Reject that combination during configuration checks. The invalid target is insufficient to predict the actual output on a bench.

The prescaler also depends on the frequency at its own input. ADI’s ADF4351 guide specifies the 8/9 prescaler above 3.6 GHz at that input. The minimum INT is 23 for 4/5 and 75 for 8/9. The first row puts 3,660.800 MHz at the prescaler, so it calls for 8/9. The second puts 915.200 MHz there, and INT=45 permits 4/5. Copying the first row’s 8/9 setting into the second would put INT=45 below that setting’s minimum. Check PFD and band-select clock limits too, and generate the full configuration for the board’s reference, loop filter and output settings. ADI ADF4350/ADF4351 guide to feedback and prescaler limits

The same carrier can sit on a different frequency grid

Keep the 20 MHz PFD, MOD=1000 and ÷4. Increasing FRAC by one moves the connector frequency by 20 MHz / 1000 / 4, or 5 kHz, with fundamental feedback. With divided feedback, the step is 20 MHz / 1000, or 20 kHz. Starting at 915.200 MHz, the first case can reach 915.205 MHz with one step. The second moves to 915.220 MHz. State the required step at the output port, then recalculate adjacent targets. If the selected grid cannot represent a target, report the rounded frequency and its offset.

When two configurations land on the same carrier, compare settling time, phase repeatability after a retune, phase noise and spurs against the project limits. If the application depends on phase with respect to the reference, check the manufacturer’s phase resync procedure and verify the trigger and timing. A lock indication and a correct center frequency leave those measurements open. ADI phase resync and timing

Match the bus capture to a measurement at the main output

For initial power-up, follow R5 → R4 → R3 → R2 → R1 → R0. For a frequency change, update the affected feedback, prescaler, fractional and reference settings together. MOD and several reference settings are double buffered and need a subsequent write to R0 to take effect. The RF divider selection in R4 is also double buffered when R2.DB13=1. If the software shows new values while the analyzer still shows the old output, capture CLK/DATA/LE. Compare the program’s register copy, the words latched at LE and the measured result. The three-wire register interface is for writes. ADI write interface and double buffering · ADI initialization sequence

Check the schematic to see whether the measured connector goes to RFOUTA or the auxiliary RFOUTB. The auxiliary output can be set to the VCO fundamental or the divided signal. The fourth harmonic of 915.200 MHz is also 3,660.800 MHz, so seeing a peak there calls for checking the spectrum’s fundamental, the port and the output selection. Wait for lock and settling, then measure both divider settings at the main output. Attach the reference and PFD values, feedback bit, divider, INT, FRAC, MOD, write sequence and port to the report. For a board RFQ, specify the reference conditions and the required range, step and phase or noise limits at the named connector. ADI main and auxiliary output controls