The instrument is already running, and the application waits for output settling after each frequency change. If the external reference never stops, an oscillator with a shorter startup time will not directly shorten that wait. The ADF4351 datasheet describes the reference input, VCO band selection, lock detection, and RF output control separately. Define the event that starts the timer and the frequency-error or amplitude criterion that ends it. Then identify which component can affect that interval.
Mark three events on the same timebase
Use a test pin or scope capture to mark when the configuration write finishes, when digital lock detect changes, and when RF enters the required error band. Keep reference power on for a series of channel changes. Run a separate cold start and log when the reference becomes valid. Mixing the two can make the slowest result include oscillator power-up that normal channel changes never perform. Record the starting frequency and step size with the trace.
Measure lock indication and usable output time independently
The ADF4351 has a band-select clock setting and a mute-until-lock option. With muting enabled, a temporarily low RF level does not establish that the reference stopped. If specifications require RF to stay within a window for a defined interval, check the actual RF output. Use digital lock detect to align events, while verifying the instrument’s accuracy requirements separately. Keep the loop filter and register settings constant during comparison.
Compare reference cold start, running reference quality, and system channel-change time in separate columns. Faster startup can directly help only if the application shuts the reference down between readings and that delay is measured. Record the supply policy and acceptance thresholds so a loop-dominated delay is not treated as a reason to buy a more expensive reference. ADI ADF4351 datasheet