An electricity meter uses an eight-channel simultaneous-sampling ADC to measure voltage and current. TI specifies a 244 ns channel-to-channel phase-delay calibration resolution for the ADS131M08 when the input clock is 8.192 MHz. Record that clock condition when comparing options. Treating 244 ns as fixed could lead to an incorrect conversion on a different board revision. The figure is the programmable delay step, and overall meter phase accuracy has other contributors.
Convert the required phase angle into time
At 50 Hz, 244 ns corresponds to about 0.0044°, because one 20 ms cycle spans 360°. At higher signal frequencies the same delay step covers a larger angle. A more accurate clock cannot automatically compensate for frequency-dependent phase shift in a sensor, current transformer, or analog filter. Confirm the input band, measurement range and permitted residual error before deciding whether the step is fine enough.
Tie the delay step to the calibration coefficients
Apply comparable signals to two inputs. Record the reference frequency, sampling configuration, and per-channel delay codes. Measure the uncorrected channel difference, then step the delay and observe the result. When a shared generator feeds paths of different length or filtering, characterize fixture mismatch before deriving production coefficients. If the clock architecture changes, recheck the data-sheet relationship and repeat calibration in the actual configuration.
In the purchasing approval record, identify the ADC and its reference configuration on the clock line, and the input clock condition for the delay step on the ADC line. Two clocks may both give valid ADC data while implying different meter calibration settings. TI ADS131M08 channel-to-channel phase-delay calibration