In a battery meter, the MCU can run from its internal clock while an independent watch crystal drives its asynchronous timer. The ATmega328P CPU and Timer2 then occupy separate clock domains. After the CPU executes a register write, the low-frequency clock may still need to carry that update into the timer. Immediately rewriting the same register or going to sleep can lead to an occasional missed wake-up that looks like slow crystal startup.
Wait for the relevant busy flag rather than estimating a delay from CPU speed
Read ASSR and identify the update-busy flag for the counter, compare, or control register just written. Wait for it to clear as required by the manual before acting on the update. Separate registers have separate flags. A fixed number of empty loops is sensitive to compiler optimization, CPU frequency, and timing of the write, so a successful debug build may not be portable.
Start with a minimal repeating firmware path. Set the compare value, wait for the specified flags, clear the required interrupt state, enter a sleep mode that supports the asynchronous timer, and wake on the compare event. Use two GPIO outputs to mark readiness and entry into the wake handler, and measure the interval. Capture enough repetitions before adding serial logs or sensor reads. Logging can introduce enough delay to hide the synchronization issue.
Also check the multiplexing of TOSC and main-clock pins and the synchronization rules for reading the count after wake-up. The processor can briefly see the value from before sleep. The manual gives a procedure for ensuring an updated read. Record when in the wake sequence the read occurred to distinguish a stalled timer from an early read. Keep the actual clock-source selection in the record so changing a part does not accidentally change pin use.Microchip ATmega328P asynchronous Timer/Counter2 operation