Specialist Supplier of Crystals & Frequency Control Componentssales@mecxtal.com.cn0755-26500570
MERLIN home / Rednote / Measurement and Acceptance

The first burst of a 19.2 MHz clock appears to sag. How do you check its actual logic levels?

A 19.2 MHz clock starts sending pulses after enable. In the first burst, the highs look healthy at first, then the whole trace drifts down and the lows appear below zero. Save the capture and trigger settings, then check the receiver pin against its local ground with DC coupling. For the first pulse, two questions matter. Does it reach the specified logic levels, and does it stay valid for long enough? The downward trace alone leaves both questions open.

The pulses arrive every 52 ns, but their average changes over the burst

AC coupling inserts a high-pass filter in the scope channel's signal path. A 19.2 MHz clock has a period of about 52.08 ns and, at 50% duty cycle, a nominal high time of 26.04 ns. The individual pulses are fast. Their cycle average can still jump from an idle level to a new average for the duration of the burst. The high-pass path attenuates this low-frequency content. For example, some Keysight InfiniiVision 1000 X-Series models specify a 10 Hz cutoff for AC coupling on their vertical inputs. Check the coupling and input impedance options available with your instrument and probe. Keysight 1000 X-Series vertical input coupling specifications, Keysight examples of AC coupling and square-wave distortion.

Consider an ideal 0 to 1.8 V clock at 50% duty cycle. Assume the line holds at 0 V during a pause long enough for the coupling network to settle. When pulses start, the input's cycle average rises to 0.9 V. With a first-order 10 Hz high-pass model, the time constant τ = 1 / (2π × 10 Hz) ≈ 15.9 ms. In the slow envelope approximation, both displayed plateaus move downward by about 0.9 × (1 − e−t/τ) V. After 10 ms, that shift is about 0.42 V. The displayed high and low can reach roughly +1.38 V and −0.42 V while still sitting about 1.8 V apart. When transmission stops, the displayed low recovers toward zero. A shorter pause leaves more of the shift in the next burst.

This is a calculation for an ideal signal and a first-order filter. A real output may idle high, be biased at another voltage or go high impedance. The direction and size of the shift depend on the idle state, duty cycle, burst length, gap and actual coupling network. Zero on an AC-coupled trace is a filtered reference. Check the same interval with DC coupling before comparing a negative-looking plateau with a receiver's voltage limits. Tektronix on low-frequency voltage changes hidden by AC coupling.

Hold the trigger and test conditions fixed while changing channel coupling

  1. Take a DC reference capture first. Probe close to the receiver with its local ground as the reference. Use a probe and input path that preserve DC, and check attenuation, input range and grounding. Choose a vertical range that includes the idle level, both plateaus, overshoot and undershoot. Keep the ground connection short. A long return lead can introduce ringing, and the shape may change when you shorten it. Tektronix on probe loading and short ground connections.
  2. Trigger from enable and keep the idle interval in view. Use a separate channel or external trigger on enable. Keep the slope, level and pretrigger interval fixed so the first pulse in each capture is referenced to the same event. Trigger coupling and waveform input coupling are separate controls. Capture the idle level, first pulse and end of the burst. A continuous 10 ms record at 1 GS/s takes about 10 million points per channel. Check the effective rate with the supply and enable channels turned on. If memory is limited and the event repeats reliably, use a long capture to locate the timing, then take fast records of the relevant intervals from the same trigger reference. If first-pulse failures are intermittent, prioritize a single deep record of the event. Rohde & Schwarz RTB 2 manual on waveform and trigger settings.
  3. Switch the clock channel to AC coupling. Keep the probe, point, bandwidth, impedance, supply, load and burst timing the same. Allow the input to settle, then compare the same burst number after the same idle interval. Read the high and low plateaus at the beginning, middle and end, and compare the idle level after the burst. If the DC-coupled plateaus stay steady and the AC-coupled high and low move together with little change in their separation, the input filter accounts for the difference. If the coupling change forces another input impedance or probe mode, check the resulting load before treating the captures as equivalent.

If the DC trace also changes, measure along the clock path

Check probe loading and the local ground first, then capture oscillator supply, enable and the receiver waveform together. A high plateau that falls at the same time as a supply disturbance points to a power or decoupling check, with causation still to verify. If the source looks steady and the receiver changes, check the intervening components, termination and receiver bias. Where the board already contains series coupling capacitors, measure both sides with a DC-coupled setup. Observe the receiver bias before, during and after the pulses. For a differential input, compare both differential swing and common-mode voltage with the receiver's specifications. TI's LMK01801 data sheet gives an example where charging the coupling capacitors in an LVDS link can affect startup timing. TI LMK01801 examples of AC coupling, bias and startup.

Judge the first pulse using the receiver's voltage and timing limits

For a single-ended logic input, compare the measured DC high and low plateaus against VIH(min) and VIL(max) at the applicable supply and temperature. Measure high and low pulse widths at the reference level specified in the receiver's timing diagram. Suppose the high must reach 1.20 V, the low must stay below 0.50 V, and the first high pulse must last at least 20 ns when measured at the specified 0.90 V timing reference. A DC capture with plateaus of 1.30 V and 0.12 V would have voltage margins of 0.10 V and 0.38 V. If its first high lasts 12 ns, it still misses the width requirement by 8 ns. Later pulses close to 26 ns cannot qualify the first one. These numbers illustrate the check. Use the actual receiver's limits for acceptance. TI on logic input limits and pulse timing reference levels.

For a result that quality or purchasing can reproduce, record the complete clock and receiver part numbers, supply, load, enable timing, idle gap, measurement point and ground reference. Include the coupling mode and effective sample rate. A separate capture at higher sensitivity can resolve ripple on the high plateau. Label the vertical range and coupling for that view. The DC reference, receiver thresholds and measured first-pulse timing remain the evidence for logic-level acceptance.

WeChat

MERLIN · TIMING COMPONENTS

Scan with WeChat to contact Sales

Add our WeCom contacts from your usual WeChat app.

On desktop, scan with your phone. On mobile, save the QR image and select it from your album in WeChat Scan.