The oscilloscope triggers in the middle of each clock burst. How long should holdoff be?

A wireless board wakes periodically and its oscillator emits a burst. Ordinary rising-edge triggering locks to different pulses and never shows the first edge consistently. Trigger holdoff is the time after a valid trigger during which new triggers are ignored. With known burst lengths and gaps, it can suppress the remaining edges after the first and allow the scope to rearm before the next burst. Too much holdoff may skip alternating bursts. Measure the timing distribution before setting it.

Separate trigger point, record length and rearm time

Rising-edge triggering simply detects a voltage crossing upward through a threshold. Any rising edge in the burst can qualify. In continuous acquisition, processing and rearming can put the next trigger anywhere in a burst. The Tektronix TBS2000B manual illustrates holdoff with pulse groups. It temporarily rejects otherwise valid events so the next group can be a candidate. Check the instrument’s definition, including timing origin, adjustment range and mode limits. The scope may remain unavailable during acquisition processing even after the holdoff interval. Compare accepted bursts using trigger output, status or segment timestamps.

Take a longer capture containing two or three full bursts. Record the maximum interval from the first edge to the last eligible edge and the minimum first-edge-to-first-edge interval. Holdoff should exceed the first and remain below the second with enough margin for event and trigger jitter. If falling edges can trigger too, locate the last candidate under the selected slope setting. Leave some pretrigger time when examining the first few cycles to see input and enable states. If a long record prevents timely rearm, try a shorter record or a mode that records the timing of successive acquisitions.

Worked example with assumed values. A training generator emits a burst about every millisecond. The longest burst is 120 µs from its first edge to its last rising edge, and the shortest measured first-to-first interval is 900 µs. Set holdoff to 200 µs. Provided the instrument rearms in time, a trigger on the first edge rejects the remaining positive edges in that burst and allows a trigger on the next first edge. With 1 ms holdoff, a burst starting 900 µs later can be skipped. With 50 µs, later edges in the same burst can still trigger. Test using another channel carrying the generator sync signal. Measure the trigger-to-first-edge interval in dozens of records. Holdoff stabilizes the display only after a trigger lands near the start. If acquisition began halfway through a burst, try triggering on enable or stop and rearm during idle.

Preserve anomalies that holdoff would suppress as triggers

An abnormal edge after the first one can be ignored as a new trigger. It remains in a record covering the full group. With a short record it can fall outside the window. For a missing or runt pulse, use a pretrigger condition and keep the entire burst. Where supported, let wake-up start a compound trigger and look for a later width or delay fault. To check whether a group comes early, measure adjacent start times directly in a long record. A stable display by itself proves only part of the setup.

With varying board load, the longest group can nearly reach the minimum inter-group interval. A single holdoff then gives too little margin. Use an independent enable pin, request signal, external trigger or sequence trigger. If no marker exists, use a single acquisition in a known idle window or a condition for the first edge after silence. Save an overview of several groups and a close-up of phase and the first pulse’s amplitude. An external wake-up command, usable oscillator output and receiver sampling may be three distinct events. Define which two are relevant to the test.

To distinguish scope skipping from skipped board bursts, log group starts with another counter or apparatus and compare them with the scope’s accepted trigger count. If fewer acquisitions occur despite the correct holdoff and continuous mode, check processing dead time and storage mode. When the trace does not retain trigger status, record the first event ID separately.

With a retained sample, verify which edge begins each record before pursuing the failure. If receiving inspection specifies startup time or minimum amplitude of early edges, record holdoff, source, threshold, pretrigger duration and group timing. After production settings change, repeat the three holdoff values to see whether the station records the first edge, an edge inside the group or just the groups that happened to land after processing.