Several controller boards communicate on a conventional CAN bus. They can also send CAN FD frames until the data rate is raised. Error counters then climb and some nodes go offline. Keep those boards and their oscillators in place while you locate the event in time. A clock mismatch between nodes is one possibility. A transmitter seeing its own bits come back too late is another. They call for different fixes.
CAN FD can use two bit rates in the same frame. Arbitration uses the nominal bit time. With bit-rate switching enabled, the data phase can use a shorter bit time. At a nominal 500 kbit/s, a bit takes 2 microseconds. A 2 Mbit/s data bit is only 500 ns. Cable propagation, reflections and transceiver latency do not shrink in proportion to the bit period. A delay that occupied a small fraction before can now consume much of the available window. Successful operation at the nominal rate is a baseline for the high-speed test.
Which node is deciding what bit it sees?
The transmitting controller sends a signal to its transceiver, which drives the differential bus. The same node receives the resulting bus state back through the transceiver and checks whether it matches its transmission. This loop takes time. At high data rates, the controller can reach its normal sampling point before the corresponding edge has returned to its receive pin. A highly accurate oscillator does not eliminate the propagation time.
ST's FDCAN application note links this problem to transmitter delay compensation, or TDC. The transmitter can check its own bit at a secondary sample point during the data phase. Its position depends on controller measurements and register settings. Receiving nodes still use their own bit timing to sample the arriving waveform. Their termination, interconnect and independent oscillator errors need separate checks. Identify which node reports the error before deciding which timing path to investigate.
Assume a 500 ns data bit and a normal sample point at 70 percent, or 350 ns after the nominal bit boundary. On one board, the feedback edge reaches the controller 380 ns after its transmit reference. The normal check would be 30 ns too early. A different transceiver might reduce the delay to 240 ns on the bench, making the same 350 ns setting appear fine. That can look like a lot-dependent fault. Calculate the production setting from the controller's compensation range, time quanta and actual transceiver timing limits.
Reproduce transmit feedback and remote reception separately
Start with two nodes, a short cable, correct termination and a repeatable frame. Keep bit-rate settings constant. On a common scope trigger, observe the controller's transmit and receive pins together. Measure several rising and falling transitions and check whether their delays differ. A differential trace at the bus alone does not show when the controller received the feedback. Repeat at relevant temperature and supply settings, preserving the measurement method and probe locations.
Then check the waveform and receive path at the remote node. If errors appear only with longer cable or more nodes, investigate the remote sampling window, reflections and branch stubs. If the error still reproduces with two nodes and a short cable, and the local feedback edge is close to the normal sample point, inspect TDC first. Try a lower data rate or another qualified transceiver as a controlled comparison. Change one item per run and keep the frame, temperature and supply as consistent as possible.
Calculate the oscillator allowance separately for the two endpoints and their bit timing. If each is allowed 20 ppm in opposite directions, their relative error can reach 40 ppm. Across five bits of 500 ns each, a simple magnitude estimate gives 0.1 ns of accumulated timing difference. The permissible error on a real network depends on resynchronization jump width, transition spacing, timing segments and temperature. This is an illustration rather than a protocol limit. It shows why a fixed feedback delay of tens or hundreds of nanoseconds merits checking the propagation path first.
For substitutions, ask purchasing to list the oscillator's full frequency, interface and accuracy over the required temperature range. For the transceiver, record maximum bit rate and propagation delay at the stated supply, temperature and test conditions. Engineering can add both timing configurations, TDC status and links to oscilloscope traces. For final acceptance, exercise the agreed frames and harness combinations with units at the relevant temperature extremes. Preserve the error counters and timing evidence so a later substitute can be retested against the same conditions.