Suppose a board laid out for a CC1101 crystal needs to run from a 26 MHz active reference. On the bench, one sample receives packets from a generator while another sometimes fails to become ready. Start with the waveform that reaches XOSC_Q1. A generator supplying a sine wave and a board oscillator supplying CMOS clock edges need different checks. Record the source swing, coupling path and timing for each setup so that another engineer can reproduce the result.
Start with the input shown in the TI data sheet
Section 7.4 specifies two forms of external reference in the 26 to 27 MHz range. Couple a sine wave into XOSC_Q1 through a series capacitor and keep the input swing at or below 1 V peak to peak. With a full-swing digital signal from 0 V to the CC1101 supply voltage, that series capacitor may be omitted. In either case, leave XOSC_Q2 unconnected and take the crystal out of the path. TI also allows the crystal load capacitors C81 and C101 to be omitted with an external source. Check the network names before removing anything from a finished board, especially if the production schematic uses different designators from the reference design.
Ask the oscillator vendor for its actual output levels and waveform. A part powered from 3.3 V might produce a digital output near 3.3 V or a clipped waveform centered at an entirely different DC level. On a CC1101 board running at 1.8 V, direct drive from a 3.3 V CMOS output falls outside the stated full-swing input condition. Consider a matching 1.8 V source or a suitable translator, and review the output levels, edges and supply sequence. A series capacitor blocks DC, so level translation for a digital path needs its own design check. For a clipped-sine candidate, obtain a waveform and test-load information and establish compatibility with TI before selecting it. Treat the output label as a request for more data.
What a generator display of 0.60 Vpp tells you
Suppose the generator has a fixed 50 Ω series output resistance and is set to display 0.60 Vpp into a matching 50 Ω load. The load sees half the equivalent open-circuit source swing, so the source swing is about 1.20 Vpp. A load close to an open circuit could see nearly 1.20 Vpp, above TI's sine-wave limit of 1 Vpp. This is a voltage-divider example. Reflections, the DC-blocking capacitor, the pin impedance at the driving frequency and the probe can change the real waveform. Read the load-setting instructions for the specific generator, then verify the voltage at Q1 with the coupling path and board supply in their actual configurations.
A high-resistance probe still has input capacitance. At 26 MHz, a nominal 10 pF input has about 612 Ω of capacitive reactance, and a 1 pF input has about 6.12 kΩ. A node driven through a relatively high source impedance may show a different swing or phase with the probe attached. Record the probe's input resistance and capacitance, grounding arrangement and scope termination. Confirm the waveform at the source, then use a suitable low-capacitance probe at Q1 and compare whether the radio starts and receives with and without the probe. Include measurement uncertainty when setting the acceptance margin below the 1 Vpp limit.
The capacitor in the signal path introduces reactance too. As a calculation example at 26 MHz, an ideal 100 pF capacitor has a reactance magnitude of about 61.2 Ω and an ideal 1 nF capacitor about 6.12 Ω. The change illustrates why the whole source and input network determines attenuation. Select the production capacitor using the source and board measurements. For real samples, compare the swing, DC operating point and startup with the intended source and assembly options. Include the capacitor’s frequency response and the layout parasitics when a measurement departs from the simple estimate.
Time the wait for SPI ready and the first valid packet
On a battery-powered board, capture the oscillator's enable or supply, the waveform at Q1, and the CC1101 CSn and SO signals together. Sections 10.1 and 19.1.1 describe observing CHIP_RDYn on SO after pulling CSn low and waiting for ready before the first rising SCLK edge. In one hypothetical trace, Q1 reaches usable amplitude 0.25 ms after source enable and SO indicates ready at 0.40 ms. If firmware starts SPI clocking at 0.30 ms, that transaction begins 0.10 ms too early for that trace. Wait for the specified ready state, handle a timeout and repeat the measurement at the lowest operating supply and the design's temperature limits. Measure cold starts and sleep recovery separately.
Checking SPI ready leaves the radio behavior to verify. Check the actual reference frequency over the design conditions, measure the carrier center and test the first packet and ongoing two-way communication with the existing gateway. Check what reaches the input when the source turns on ahead of the CC1101 supply, or when the radio supply turns off first. Record how the circuit and firmware sequence the drive. If sensitivity changes after the conversion, run controlled comparisons of the reference source, probe hookup and RF setup before attributing the change to the oscillator.
Approve a specific oscillator and a specific schematic
In the RFQ, ask for the complete ordering code, output waveform, guaranteed voltage levels, test load and supply range. Check pinout, frequency stability and temperature range. For a clock with an enable pin, get the logic polarity, voltage requirements, output state when disabled and guaranteed startup time. The approved engineering record should identify the Q1 coupling components, Q2 left unconnected, board revision and actual measurement setup. If the prototype used a generator, repeat the production acceptance test with the intended oscillator fitted to the board. Approve alternative part numbers against that same interface and interoperability record.
See the TI CC1101 data sheet SWRS061I, sections 7.4, 10.1 and 19.1.1 and Keysight’s output-load documentation. If the reference frequency is also changing from 26 MHz to 27 MHz, see MERLIN’s CC1101 channel calculations for the firmware-side checks.