Two CC1101 nodes communicate on a bench at a nominal 433.92 MHz. Before relaxing the tolerance of the next lot of 26 MHz crystals, try a high-side transmitter against a low-side receiver or simulate that pairing with calibrated test equipment. Two units from one lot can drift in the same direction. Their errors largely cancel when paired, even if either would be harder to use with a field gateway from another lot.
Express the errors on a common RF frequency scale
The transmit carrier and receive local oscillator each depend on the local reference. Let fRF be the nominal channel frequency and let eTX and eRX be the reference errors in ppm. With an intermediate frequency small compared with the carrier, the extra receive offset is approximately fRF × (eTX − eRX) / 106. For a more precise calculation, multiply each error by the nominal frequency of the carrier or the receive local oscillator it belongs to and then subtract. TI design note DN005 uses this relationship to explain why the receiver filter needs room for the offset.
In an illustrative 433.92 MHz channel, one ppm is 433.92 Hz. Suppose each reference has a total budget of ±40 ppm. This is ±1,040 Hz at the 26 MHz crystal and about ±17.36 kHz when expressed at RF for one side. A transmitter high by 40 ppm and receiver low by 40 ppm create about +34.71 kHz of receive offset. The opposite pairing creates about −34.71 kHz. The full separation between the two ends of that test is about 69.43 kHz. DN005 charts can report the full span. A single test of an offset in one direction uses the corresponding one-sided value.
| Transmit error | Receive error | Relative reference error | Approximate receive offset |
|---|---|---|---|
| +40 ppm | −40 ppm | +80 ppm | +34.71 kHz |
| −40 ppm | +40 ppm | −80 ppm | −34.71 kHz |
| +26 ppm | +24 ppm | +2 ppm | +0.87 kHz |
| +32 ppm | −23 ppm | +55 ppm | +23.87 kHz |
In the third row, the relative error is only about 0.87 kHz even though the transmitter is about 11.28 kHz above the nominal channel center. Record each unit's absolute deviation against a calibrated reference so the result can be compared with a different production pair. Keep register quantization and any applied offset correction visible as separate items. A correction already included in the measured error should be accounted for once.
Work back from an observed receiver limit
The CC1101 data sheet treats crystal accuracy as a total that includes initial variation, loading, temperature and aging. The acceptable value depends on the operating frequency and the channel spacing or bandwidth. The receiver's channel filter has to accommodate the modulated signal as well as the center-frequency offset. Test the intended modulation, data rate, filter and compensation settings. Sweep offsets in both directions near the product's low-signal acceptance level and record how sensitivity or packet error rate changes. Choose the more restrictive side for a symmetric budget. Use a calibrated source and account for the offsets of the instruments and units under test.
Suppose the stricter single-sided limit in that hypothetical test is 28 kHz, and engineering reserves 4 kHz for remaining configuration errors and test allowances outside the reference allocation. This leaves 24 kHz, or about 55.31 ppm at 433.92 MHz, for both reference paths together. An equal split is about 27.65 ppm each. A conservative working allocation of ±27 ppm per end produces a worst relative reference offset of about 23.43 kHz. When one end is a fixed production gateway, use its verified worst case to set the remaining node allowance. There is no need to force an equal split.
Start the receiver test at nominal frequency, then apply positive and negative offsets while keeping packet length, counting rules and input signal level fixed. In one illustrative test, 12 missed packets out of 400 on the positive side give a measured packet error rate of 3.0%. One miss on the negative side gives 0.25%. A product target of 1% leads to different decisions at those two settings. Keep the applied RF frequencies and packet counts with the result. Take finer steps around a boundary and repeat at the product temperature and signal level limits. If the asymmetry appears only with one firmware image, verify the frequency compensation and digital filter before changing the crystal order requirement.
Turn the result into separate part and board requirements
For that 27 ppm example, an allocation could be 10 ppm initial error, 8 ppm change over the operating temperature range, 4 ppm residual error from the installed load and 5 ppm aging over the agreed service interval. Add the maximum magnitudes for a conservative budget. If the supplier guarantees one combined limit for initial and temperature variation, use that value in place of the corresponding rows. Ask for the temperature reference, load, age or aging interval and whether the number is a guaranteed limit. Allocate the load contribution from board measurements separately from the bare crystal specification.
Request the complete ordering code, package drawing, rated load, ESR at 26 MHz and drive limit. For release, pair known high-side and low-side samples in both roles and run packet measurements at the specified low signal level. Log absolute frequency error, attenuation, register values, data rate and the sign of the applied deviation. Store the setting alongside the BOM and firmware revision used on the test units. If the project is also moving to a 27 MHz reference, regenerate the affected channel and modem settings and qualify that version separately.
See TI CC1101 data sheet SWRS061I, sections 4.4, 14.1 and 21 and TI DN005, sections 2 through 5. For a change of reference frequency, see MERLIN’s CC1101 channel register example.
