Why can only a few CC1120 channels lose sensitivity with a healthy 32 MHz crystal?

A CC1120 narrowband receiver shows more packet errors at some channels than others at the same bench input level. The 32 MHz crystal measures on frequency. Before ordering a tighter reference, compare each affected channel with the multiples of the master clock. TI describes frequency relationships that can affect receiver sensitivity and transmitter spurs. Check their separation independently of the oscillator tolerance.

Check different distances in receive and transmit

The crystal-oscillator section of the data sheet warns of degraded receiver sensitivity near multiples of half the crystal frequency. TI recommends keeping the receive channel at least half the receiver bandwidth away from those points. For transmit, TI recommends evaluating spurs when the RF channel is less than 1 MHz from a multiple of the full crystal frequency. Apply the criteria to the correct signal path. Use a suitable conducted or shielded setup for emissions work and follow the product's authorized test plan.

With a nominal 32 MHz crystal, the receiver comparison points are 16 MHz apart. One is 432 MHz, equal to 27 times 16 MHz. At a 25 kHz receiver bandwidth, half is 12.5 kHz. An illustrative lab frequency of 432.010 MHz is 10 kHz from that point. At 432.030 MHz, the spacing is 30 kHz. These calculations screen channel locations. They do not replace sensitivity measurements.

For transmit, 448 MHz equals 14 times 32 MHz. A lab setting 0.6 MHz away falls within the manufacturer's suggested spur-evaluation distance. One 1.2 MHz away does not trigger that particular distance check. Both still need to meet the product's applicable requirements. Retain separate columns for the nearest half-reference and full-reference multiples and their offsets.

Control the bench setup before changing the reference

Keep the generator, attenuation and cabling fixed. Compare several receive frequencies using the same bandwidth, rate, framing and packet count or test time, with a calibrated signal level at the board. Record the actual crystal and RF settings. If the sensitivity drop tracks proximity to a reference multiple, add a nearby control point farther away. If all channels degrade together, also investigate power, matching and the test path.

At 20 ppm, a 32 MHz clock could vary by ±640 Hz in this example. Its half-frequency varies by ±320 Hz, and a theoretical point at 27 times that half-frequency varies by ±8.64 kHz. A channel synthesized from the same reference can also move. Do not apply the full theoretical movement to the separation without considering which reference sets the RF channel or bench source. Compare measured values captured under the same conditions.

A same-frequency 32 MHz TCXO can improve reference stability, while the basic multiplier relationships remain. TI specifies different circuits for a passive crystal and an active reference. The passive part connects across the oscillator pins. The external clock connection depends on its output type. A direct-coupled CMOS output and an AC-coupled clipped-sine source have different requirements. Qualify actual levels, edges, supply current and the enable behavior before repeating the channel tests.

For a transmit comparison, preserve the analyzer settings, including attenuation, resolution bandwidth, detector, span and acquisition time. Compare channels at the same expected output level. If a spectral line disappears when the analyzer attenuation is increased, check whether the analyzer was generating a product due to overload. Repeat with the same RF matching circuit and save the full trace and settings.

For receive, complete the channel comparison at the product's nominal bandwidth first. A second approved bandwidth may be useful as a separate experiment if it still passes the chosen waveform. Changing bandwidth changes noise and can truncate the signal, so record those results separately. Retain the actual channel and nearest reference multiple beside every observation.

Keep channel verification in the board-level acceptance plan

For a passive crystal, retain the complete order code, load capacitance, ESR and frequency budget. For a TCXO, document output type and operating range. Engineering should record the synthesized frequencies, receive bandwidth, reference board revision, worst-case sensitivity and observed spurs. Start with a near-multiple and a far-from-multiple comparison. If the failures follow the frequency relationship, review the channel plan and receiver settings before qualifying a new reference frequency. This gives purchasing a precise part requirement and gives engineering a health check for the assembled system.